SINGLE 01.06.2019
English / Englisch
COMMISSIONING
4
Additionally applies to machines with three-phase AC motor
(mains voltage 400 V)
If the motor does not start after the two start levers have been
pulled at the same time and the red LED light on the machine
housing shines (fig. 15), the rotation direction of the motor must
be changed. In order to do this, proceed as follows:
1
Disconnect the motor cable from extension cable!
2
Original
LÄGLER
®
plug with
red
nut at the cable outlet
(fig. 16,
A
):
- Put a screwdriver in the slit of the phase changing switch
in the plug of the motor cable (fig. 17, 1).
- To unlock the phase changing switch press the screwdriver
in the slit and at the same time turn the screwdriver 180°
(fig. 17, 2).
Original
LÄGLER
®
plug with
yellow
nut at the cable outlet
(fig. 16,
B
):
- Put a screwdriver in the slit of the phase changing switch
in the plug of the motor cable (fig. 17, 1).
- To unlock the phase changing switch turn the screwdriver
180° against a small resistance (fig. 17, 2).
ATTENTION!
The phase changing switch can only be turned in one
direction! The corresponding direction can be different with
different plugs!
Fig. 16
Original LÄGLER
®
plug with
red
nut (
A
) or
yellow
nut (
B
).
A
A
B
B
B
Fig. 17
Change the rotation direction of the motor by
turning the phase changing switch 180°.
400 V
2
180°
11
Fig. 15
The motor does not start and the red LED light on
the machine housing shines.
400 V
23