UNICO 01.07.2019
English / Englisch
This section shows you how to remedy possible malfunctions. If
none of the measures listed here are successful, please contact
our service department, your retailer or your importer.
9.1 THE MACHINE IS NOT RUNNING
9.1.1 THE MACHINE DOES NOT START UP
•
Check the power supply and provide if necessary (Is the plug
of the extension cable in the socket? Is the coupling between
the motor cable and the extension cable detached? Cable
breakage?).
•
Check the protection by fuses.
•
Have the electrical equipment checked by an expert
electrician (e.g. capacitor, self-locking, cables and switches).
•
The machine has been switched off via temperature sensors
and must cool off.
9.1.2 THE MACHINE ATTEMPTS TO START UP BUT IS BEING
RESTRAINED
•
At low temperatures: Heat up the machine in a warm room
to room temperature.
•
Undervoltage: Check the cable quality and cable length;
excessively small cable cross-sections (stranded conductor
cross-sections smaller than 1.5 mm²) and excessively
long supply cables must be avoided; if appropriate, use a
transformer (part number 708.00.00.100 for 230 Volts).
•
Check the V-belt tension
adjust, if appropriate.
•
Check the machine for clogged-up parts and deposits
clean, if appropriate.
•
Check the driving elements for easy movement.
Troubleshooting
9
TROUBLESHOOTING
WARNING!
RISK OF DEATH from electrical shock:
Work on the electrical equipment is to
be conducted exclusively by a qualified
electrician!
The machine must be switched off and
the power plug removed from the socket
during this work!
The circuit diagram valid for your machine
is located in the motor switch box!
RISK OF INJURY due to unsuitable parts:
Make sure that only original LÄGLER
®
spare parts and original LÄGLER
®
acces-
sories are used!
52