Electrical connection
Note the machine is not supplied with an electrical cord or plug, as the
size of the cable and the type of plug will be dependent on the
installation.
A qualified electrician must carry out the electrical installation. The main
connection should be made using the terminal box shown. Ensure that the
main supply corresponds with that of the machine, single phase or three-
phases. Use wiring suitable for the power of the motor, which is 230 volts, and
the cable is required.
Phase
Distance
Wiring suggested
1 phase
0-10 ft
12/3
1 phase
10-15 ft
10/3
1 phase
15+ ft
8/3
3 phase
0-10 ft
12/4
3 phase
10-15ft
10/4
3 phase
15+ ft
8/4
All
machines require the minimum of a 30-amp circuit breaker regardless of
the phase.
Connect the electrical wires to the terminals opposite the wires going to the
machine. On a single-phase machine you will find 3 wires. On a 3-phase
machine you will find 4. On the machine you will see a wire that is yellow and
green, which is the ground wire; the other colored wires are power. In either 1-
phase or 3-phase it does not matter what color combination you use. Green is
ground; all other wiring is power (there is no neutral). On single-phase the
wiring can be interchanged as you wish; it would not affect the rotation of the
Summary of Contents for 16HD Classic
Page 2: ......
Page 6: ......
Page 9: ...9 What you will receive with the bandsaw Tool Kit Fence table insert and door guard Table...
Page 36: ...36 Fitting cool block guide system Optional not supplied with the machine...
Page 41: ...41...
Page 58: ...58 Electrical system drawing with switch ON knob...
Page 59: ...59 Electrical system drawing with switch ON knob...
Page 60: ...60 Electrical system drawing with push ON button...
Page 61: ...61 Electrical system drawing with push ON button...
Page 63: ......
Page 64: ......
Page 65: ......
Page 66: ...TOP GUIDE BOTTOM GUIDE...
Page 99: ......