F1 Table Saw
9
Grounding Instructions
Table A
Ampere Rating
Volts
Total length of cord in feet
120
25
50
100
150
240
50
100
200
300
More Than
Not More
Than
Minimum gage for cord
0
6
18
16
16
14
6
10
18
16
14
12
10
12
16
16
14
12
12
16
14
12
Not Recommended
Grounding Methods Provided by CSA Group. (A) Receptacle with nominal rating less than 150 volts. (B) 150
volt receptacle without grounding pin fitted with adapter. (C) Grounding receptacle adapter. (D) Receptacle
with nominal rating between 150 - 250 volts.
All grounded, cord-connected tools:
In the event of a malfunction or breakdown, grounding provides a path of least resistance for electric
current to reduce the risk of electric shock. This tool is equipped with an electric cord having an equipment-
grounding conductor and a grounding plug. The plug must be plugged into a matching outlet that is properly
installed and grounded in accordance with all local codes and ordinances.
Do not modify the plug provided; if it will not fit the outlet, have the proper outlet installed by a qualified
electrician.
Improper connection of the equipment-grounding conductor can result in a risk of electric shock. The
conductor with insulation having an outer surface that is green with or without yellow stripes is the
Summary of Contents for Fusion F1
Page 26: ...F1 Table Saw 26 Put on the fence and calibrate it by loosening and moving the scale...
Page 33: ...F1 Table Saw 33 Parts Table Fence Rails...
Page 34: ...F1 Table Saw 34 Blade Guard Miter Gauge...
Page 35: ...F1 Table Saw 35 Fence...
Page 36: ...F1 Table Saw 36 Base...
Page 37: ...F1 Table Saw 37 Motor Trunnions...
Page 38: ...F1 Table Saw 38 Cabinet Arbor...