19
Compression” router bit. With this bit, the up shear portion of the bit is less than ¼” in len
gth
so that the bit can be used on ¼” veneered plywood and for dados.
5.
Form Router Bits
Form Router Bits typically are available in standard profiles such as round over, ogee, etc.
Router bits that have a shape associated with them would be classified with this group
Controller button functions
Note.
There is a comprehensive manual for the hand-held
controller. Below is a list of the main key functions.
Note. The controller may vary form that shown.
X+ / 1
= Moves the gantry in the X direction away from the
home end of the bed.
Y+ / 2
= Moves the gantry in the Y direction away from the
home end of the bed.
Z+ / 3
= Moves the router head in the Z [Up direction]
away from the table surface.
XY-0 / 4
= Sets
machine “Origin”
.
X- / 5
= Moves the gantry in the X direction towards the
home end of the bed.
Y- / 6
= Moves the router head in the Y direction towards
the home end of the bed.
Z- / 7
= Moves the router head in the Z (Down direction)
towards the table surface.
Z-0 / 8
=
Used set the tool to the “Zero” surface (tool
“touch
-
off”
.)
HOME / 9
=
Causes the machine to move to the “Home” position,
first in the Z axis, followed
by X and then Y. (Home is a mechanically determined position using mechanical
switches/sensors.)
HIGH/LOW / 0
= Toggles jogging speeds between High and Low ranges.
ONOFF/.
= Turns the Router Spindle On and Off.
MENU / _
= Provides access to various setup features.
ORIGIN /OK
=
Use to accept commands (“On”
.) Origin causes machine to the machines
“Origin”.
MODE
= Toggles between the three jogging modes: Continuous, Step or Distance.
"RUN/ PAUSE / DELETE"
= Used to load a program from either the USB drive or internal
memory. While the program is running, causes the
Operation to “Pause”.
STOP / CANCEL
= Stops a running program. Also used to cancel commands.
Controller
Note The controller may vary
from that shown
Summary of Contents for MCNC Swift 60 X 120-0233
Page 2: ......
Page 11: ...11 Spare drive belts Dust hood Wrenches Table clamps qty 8 Coolant container...
Page 30: ...30 Control cabinet Spindle inverter 24 volt power supply Control cabinet...
Page 32: ...32 Motor drivers 80 Volt power supplies Terminal strip Main power disconnect...
Page 35: ...35 1 Machine not level on the floor Re level the machine ensuring that it has no movement...