1.5HP Mobile Dust Cyclone Manual
12
DO NOT EXPOSE THE MACHINE TO RAIN OR OPERATE THE MACHINE IN DAMP
LOCATIONS.
MOTOR SPECIFICATIONS
Your machine is wired for 110 volts, 60 HZ alternating current. Before connecting the
machine to the power source, make sure the switch is in the "OFF" position. An (appx.)
8’
cord is included, a
“plug” is NOT included.
A plug must be installed by a qualified
technician.
GROUNDING INSTRUCTIONS
THIS MACHINE MUST BE GROUNDED WHILE IN USE TO PROTECT THE OPERATOR FROM
ELECTRIC SHOCK.
1
. This appliance must be connected to a grounded metal, permanent wiring system; or
an equipment-grounding conductor must be run with the circuit conductors and connected
to the equipment-grounding terminal or lead on the appliance.
The installer, such as a qualified electrician, cut (or bend over) and insulate the grounding
conductor from a field wiring supply cable.
In the event of certain types of malfunctions or breakdowns, grounding provides a path of
least resistance for electric current
—
to reduce the risk of electric shock.
Improper connection of the equipment-grounding wire can result in a risk of electric
shock. The wire with green insulation (with or without yellow stripes) is the equipment-
grounding wire. If repair or replacement of the power cord or plug is necessary, do not
connect the equipment-grounding wire to a live (current carrying) terminal.
Check with qualified electrician or service personnel if you do not understand these
grounding requirements, or if you are in doubt about whether the tool is properly
grounded. If you ever notice that a cord or plug is damaged or worn, disconnect it from
power, and immediately replace it with a new one.
Full Load amperage Draw
Amp draw at 110V (prewired).................. 18.8 Amps
Amp draw at 220V ................................ 9.4 Amps
Summary of Contents for PFLUX1
Page 12: ...1 5HP Mobile Dust Cyclone Manual 11 Figure 2 110 Volt Internal Wiring ...
Page 35: ...1 5HP Mobile Dust Cyclone Manual 34 220 Volt Wiring Diagrams Figures 21 22 OPERATION ...
Page 44: ...1 5HP Mobile Dust Cyclone Manual 43 Figure 48 Fan Motor Switch SECTION A Close up view ...
Page 45: ...1 5HP Mobile Dust Cyclone Manual 44 Figure 49 Cyclone Canister Barrel SECTION B Close up view ...
Page 46: ...1 5HP Mobile Dust Cyclone Manual 45 Figure 50 Panels Lock SECTION C Close up view ...
Page 47: ...1 5HP Mobile Dust Cyclone Manual 46 Figure 51 Barrel insert SECTION D Close up view ...