LAGUNATOOLS.COM
21
POWER SUPPLY
Power Supply Circuit Requirements
The power source circuit for your machine must be g r o u n d e d and
r a t e d f o r the am p erage given
below. Never replace a circuit breaker
on an existing circuit with one of higher amperage without consulting a
qualified electrician to ensure compliance with wiring codes.
If you are
unsure about the wiring codes in your area or you plan to connect
your machine to a shared circuit, consult a qualified electrician.
Circuit Size
(208-230V, 3 Phase) .................
50 Amp
minimum
IN ALL CASES, MAKE CERTAIN THE RECEPTACLE IN QUESTION IS PROPERLY
GROUNDED. IF YOU ARE NOT SURE, HAVE A QUALIFIED ELECTRICIAN
CHECK THE RECEPTACLE.
MOTOR SPECIFICATIONS
The standard main motors are 7-1/2 HP and are typically wired for 208-230
Volt, Three Phase, 60 HZ, AC current. Confirm your motors electrical
configuration before connecting power! Before connecting the machine to the
power source, make sure the starter and switches are in the "OFF" position.
Cord and “plug” are NOT included. These must be installed by a qualified
technician/electrician to all applicable codes.
Figure 11: Electrical Connection Box
Summary of Contents for SuperMax SuperBrush 24 x 2
Page 1: ...OWNERS S MANUAL SuperBrush 24 x 2 SuperBrush 36 x 2 Lagunatools com...
Page 25: ...LAGUNATOOLS COM 25 INTERNAL WIRING Figure 15 Internal Wiring...
Page 34: ...LAGUNATOOLS COM 34 Exploded Views STAND ASSEMBLY 1of 2 Figure 22 Stand Assembly...
Page 39: ...LAGUNATOOLS COM 39 HEAD ASSEMBLY Front 1 2 Figure 24 Head Assembly Front 1 2 without brush...
Page 42: ...LAGUNATOOLS COM 42 CONVEYOR ASSEMBLY Figure 25 Conveyor Assembly...