PX|22 Sheartec:II Planer \ Setup Assembling
Power Supply Circuit Requirements
The power source circuit for your machine must be grounded and rated for the amperage given below.
Never replace a circuit breaker on an existing circuit with one of higher amperage without consulting a
qualified electrician to ensure compliance with wiring codes. If you are unsure about the wiring codes in
your area or you plan to connect your machine to a shared circuit, consult a qualified electrician.
Circuit Size (7.5 HP, 208-230V, Single Phase) ........40 Amp (minimum)
Circuit Size (10 HP, 208-230V, Three Phase)….35 Amp (minimum)
DANGER!
IN ALL CASES, MAKE CERTAIN THE RECEPTACLE IN QUESTION IS PROPERLY GROUNDED. IF YOU ARE NOT SURE,
HAVE A QUALIFIED ELECTRICIAN CHECK THE RECEPTACLE.
Motor Specifications
The typical main motor is 7.5 HP and is typically wired for 220 Volt, Single Phase, 60 HZ, AC current. An
optional 10 HP, Three Phase motor is optional. Confirm your motor electrical configuration before
connecting power! Before connecting the machine to the power source, make sure the starter and switches
are in the "OFF" position. Cord and “plug” are NOT included. These must be installed by a qualified
technician/electrician to local codes.
NOTICE! A “plug” and cord are NOT included and must be installed by a qualified technician/electrician or
the power cable connected (hard wired) to an appropriate disconnect according to local codes.
WARNING
WHEN COMPLETED, THE MACHINE MUST CONFORM TO THE NATIONAL ELECTRIC CODE AND ALL LOCAL CODES AND
ORDINANCES.
Connecting Power (See also wiring diagram page 33)
1. Remove screws securing cover to connection box.
2. Insert power cable through strain relief, tighten cinch nut and attach wires to terminals.
3. Re-install the connection box cover, see page 33 for wiring diagram.
WARNING
DISCONNECT POWER SUPPLY TO PLANER BEFORE CONTINUING! ONLY CONNECT POWER WHEN REQUIRED.
Summary of Contents for MPLANPX2210-0130
Page 1: ...PX 22 Sheartec II Planer Owner s Manual MPLANPX2275 0130 MPLANPX2210 0130 3 10 2021...
Page 25: ...25 PX 22 Sheartec II Planer Setup Assembling FIGURES 10 12 DRO ADJUSTMENT...
Page 38: ...38 PX 22 Sheartec II Planer Wiring...
Page 39: ...39 PX 22 Sheartec II Planer Wiring...
Page 41: ...41 PX 22 Sheartec II Planer Replacement Parts Diagram Table Lift...
Page 42: ...42 PX 22 Sheartec II Planer Replacement Parts Diagram Stand Motor...