8
S
ETTING
U
P
The
drum sander was adjusted and aligned at the
factory, and it has been carefully packed for
shipment. However, because of possible stress
during transit, the unit should be thoroughly
checked before use. This section covers the pre-
operational checks you should make after
unpacking and final assembly. Unnecessary
problems can be avoided if these essential checks
are performed before operating the sander.
Likewise, performing the recommended monthly
maintenance procedures listed at the end of this
section will help assure trouble-free service.
M
AKING
E
LECTRICAL
C
ONNECTIONS
A cord and plug are not included. Consult with
an electrician and confirm all applicable
electrical codes before wiring. Please see wiring
diagrams for details.
Single Phase:
The drum(s) of all S
UPERMAX
single phase sanders are powered by a 5 HP, 208-
230 volt, single phase motor. A plug and cord
is not supplied. Single phase S
UPER
M
AX
sanders require a minimum dedicated circuit of
10-gauge wire protected by a 30-amp fuse or
breaker. Extension cords are not
recommended, but if used, should be of at
least 10-gauge wire for lengths up to 10' and
of at least 8-gauge wire for longer lengths.
Views of junction box (under conveyor motor) with cord
installed.
Remove the cover of the conduit box, located
on the underside of the conveyor motor
housing, by removing the screws securing the
cover.
1.
Loosen (do not remove) the tension nut of
the strain relief bushing.
2.
Feed the new cord through the strain relief
busing.
3.
Attach the first HOT (black) wire to the
terminal, by lifting the orange clamp,
inserting the bare wire. Press down on the
orange clamp to secure wire. Attach the
second HOT (red, or white*) in the same
manner. See Figs. A & B.
CAUTION: Confirm the wire is secure in the
terminal clamp and there is no exposed non-
insulated wire!
4.
Attach the GROUD (green or green &
yellow) to the ground screw of the conduit
box. Confirm the wire is secure.
5.
Tighten strain relief nut. Confirm the
power cord is secure.
6.
Confirm all electrical connections are
secure and tight. Confirm wires are within
conduit box and will not be pinched.
7.
Re-attach conduit box cover and secure
with screws.
*Follow NEMA/local codes when using
“white” as HOT.
Fig. B. Installed Wiring
Fig. A. Installed Wiring
Summary of Contents for SuperMax 25x2
Page 1: ...OWNERS S MANUAL 25x2 SuperMax Drum Sander LagunaTools com...
Page 36: ...36 STAND ASSEMBLY...
Page 39: ...39 DUAL DRUM HEAD ASSEMBLY...
Page 43: ...43 CONVEYOR MOTOR...
Page 45: ...45 CS DE S CURIT...