MOTOR SPECIFICATIONS
The typical main motor is 10 HP and is wired for 208-230 Volt, Three-Phase,
60 HZ, AC current. Confirm your motor electrical configuration before
connecting power! Before connecting the machine to the power source, make
sure the starter and switches are in the "OFF" position. Power Cord and
“plug” are
NOT included. These must be installed by a qualified
technician/electrician to meet all applicable codes.
Confirm electrical configuration (Voltage & Phase) of brush machine before
connecting to power source!
GROUNDING INSTRUCTIONS
THIS MACHINE MUST BE GROUNDED WHILE IN USE TO PROTECT THE
OPERATOR FROM ELECTRIC SHOCK.
1
. This machine must be connected to a grounded metal, permanent wiring
system; or an equipment-grounding conductor must be run with the circuit
conductors and connected to the equipment-grounding terminal or lead on
the appliance.
The installer, such as a qualified electrician, shall cut (or bend over) and
insulate the grounding conductor from a field wiring supply cable.
In the event of certain types of malfunctions or breakdowns, grounding
provides a path of least resistance for electric current
—
in order to reduce the
risk of electric shock.
Improper connection of the equipment-grounding wire can result in a risk of
electric shock. The wire with green insulation (with or without yellow stripes)
is the equipment-grounding wire. If repair or replacement of the power cord
or plug is necessary, do not connect the equipment-grounding wire to a live
(current carrying) terminal.
Check with a qualified electrician or service personnel if you do not understand
these grounding requirements, or if you are in doubt about whether the tool is
properly grounded. If you ever notice that a cord or plug is damaged or worn,
disconnect it from power, and immediately replace it with a new one.
Full Load Amperage Draw;
208V 3 Phase ...........................29 Amps
Summary of Contents for SuperMax SuperBrush 49
Page 1: ...OWNERS S MANUAL SuperBrush 49 Lagunatools com...
Page 23: ...LAGUNATOOLS COM 23 WIRING DIAGRAMS POWER CONNECTIONS Figure 14 Power Connections Wiring...
Page 24: ...LAGUNATOOLS COM 24 INTERNAL WIRING Figure 15 Internal Wiring...
Page 30: ...LAGUNATOOLS COM 30 Exploded Views STAND ASSEMBLY Figure 22 Stand Assembly...
Page 33: ...LAGUNATOOLS COM 33 HEAD ASSEMBLY Figure 23 Head Assembly without brush...
Page 35: ...LAGUNATOOLS COM 35 CONVEYOR ASSEMBLY Figure 24 Conveyor Assembly...