6)  Mask for adults
7)   Mask for children
8) Air filters

CLEANING AND DISINFECTING

Wash your hands well before beginning to clean and disinfect the accessories.
Do not wash the apparatus under the tap or by soaking. If it needs cleaning, just use a 
cloth dampened with detergent (not abrasive and not solvent). 
Device with enclosure not protected against the penetration of liquids.

 

To disinfect the accessories, it is possible to use denatured spirit or a hypochlorite solution 
that can be easily purchased at any chemist’s shop.
Before and after each use, clean all nebuliser components (exception made for the air 
tube) removing any medical product residuals or any dirt deposits. 
Clean all components with lukewarm water and/or neutral soap; rinse them carefully 
removing excess water and let them dry in the open air in a clean place. Never boil the 
accessories. 
To dry the humidity or condensate present in the air tube, switch on the device for 2/3 
minutes letting only the tube connected; otherwise, let it dry at open air in a clean place. 
Clean the external part of the tube with a wet cloth. 

Replacement of the spare filter:

 Air filter has to be replaced every 500 hours of 

operation or in any case when the same is rather dirty. It is suggested to replace the filer 
every time that the ampoule is replaced (about every 6 months).
 Do not wash the used filters to reuse them again. 
To replace the filter, lift the filter holding cover, remove the filter to be replaced and insert 
the spare one. 
Then, insert the filter holding cover in its proper seat letting it adhere well to the surface. 
Use only original Laica filters.

Cleaning of the ampoule:

 see ampoule instruction section

MICROBIC CONTAMINATION

In the presence of conditions carrying the risk of microbial infection and contamination, 
personal use of the accessories and nebulizer only is advised (always consult a doctor).

PROBLEMS, CAUSES AND REMEDIES

The apparatus does not turn on:
•  ensure the plug is well into the socket.
•  ensure the switch is in the on position (I).

The apparatus is alight but does not nebulize:
•  ensure the air connection tube is not squashed or bent.
•  ensure the air suction filter is not blocked or dirty. If necessary, replace with a new 

one.

•  ensure the required drug is inside the bulb.
•  make sure that the ampoule is not clogged; then, clean and disinfect the ampoule as 

indicated in the manual. If the washing was not successful, replace the ampoule.

•  make sure that the nozzle is not badly mounted; press firmly with a finger on the 

nozzle (cylindrical sleeve), which is positioned within the polycarbonate ampoule 
bottom.

The appliance atomises slowly:
•  the medicinal product may be very oily. Dilute the medicinal product using 

physiological saline.

The appliance is noisy after prolonged use:
•  Refer to the dealer.
The appliance does not work:
•  the appliance has worked close to heat sources or in environments with a temperature 

exceeding 40°C. The thermal protection has tripped. Let the appliance cool for at 
least 60 minutes and then switch on the appliance again.

N.B. if the apparatus still does not work correctly, contact the retailer.

HOW TO RETURN ITEMS 
In compliance with the new European Regulations, LAICA lists here below 
some essential points to preserve the hygiene of appliances and operators 
using the same. 
LAICA relies on the observance of these procedures to assure the hygiene 
and health of all people operating in order to obtain quality and wellness.

Each appliance that shall be returned to LAICA shall be subject to hygienic controls before 
technical service. In case of goods return for replacement, it is COMPULSORY to: 
•  disinfect carefully the external part of the main unit using a cloth moistened with 

denatured spirit or a hypochlorite solution.

•   disinfect the accessories plunging them in the same disinfecting solutions.
•  insert everything in a bag specifying “appliance with disinfected accessories”.
• 

always

 specify the detected defect before returning the product.

TECHNICAL SPECIFICATION

Piston electrocompressor with thermal cut-out

13

Instructions and guarantee

GB

English

Summary of Contents for NE2007

Page 1: ...aica it TAGLIANDO DI CONTROLLO NE2007 APPARECCHIO A PISTONE PER AEROSOLTERAPIA LAICA S p A Viale del Lavoro 10 Fraz Ponte 36021 Barbarano Vicentino VI ITALY Fax 39 0444 795324 Made in China HI16 b 06...

Page 2: ...SOL THERAPY Instrucciones y garant a APARATO DE PISTON PARA AEROSOLTERAPIA Anleitungen und garantie KOLBEN VORRICHTUNG Z R AEROSOL THERAPIE Juhised ja garantii Instruc iuni i garan ie APARAT CU PISTON...

Page 3: ...4 Made in China ANNI DI GARANZIA ANS DE GARANTIE YEARS GUARANTEE ANOS DE GARANTIA JAHRE GARANTIE XPONIA E YH H ANI DE GARAN IE Data Date Timbro rivenditore Cachet du revendeur Retailer s stamp Sello d...

Page 4: ...IONE 1 Tubetto Collegamento Aria 2 Corpo Inferiore Ampolla 3 Ugello di Nebulizzazione 4 Corpo Superiore Ampolla Fig 2 Fig 3 Fig 1 SOSTITUZIONE DEL FILTRO REPLACEMENT OF THE FILTER 5 Boccaglio 6 Masche...

Page 5: ...immediately 9 Always contact the retailer for any repairs Do not open or tamper with the apparatus If it does not work properly turn it off and consult the instruction handbook 10 Place the device on...

Page 6: ...n ensure the plug is well into the socket ensure the switch is in the on position I The apparatus is alight but does not nebulize ensure the air connection tube is not squashed or bent ensure the air...

Page 7: ...e fiscal payment receipt that shall be kept enclosed to this document This warranty period complies with the laws in force Italian legislative decree No 24 dated Feb 02 2002 and following Consumers Ac...

Page 8: ...nter clockwise and remove it Pour the quantity of medication prescribed by your doctor into the nebulizer tank IMPORTANT In case you do so empty the nebulizer clean it thoroughly and proceed with new...

Reviews: