47
USER GUIDE
9 - CONTROL PANEL
9.1 Ecovip and Kreos series
Main screen
1) On/off main switch (to turn on/off press for two
seconds). If the relevant LED is green the control
panel is on, if it is red an alarm is on (batteries,
tanks, etc.).
2) Button for control of engine and auxiliary
batteries voltage (in Volt) and for the setting of
the programmable parameters (see “Setting”).
3) Button for the control of fresh, waste and
additional (optional) water tanks, for fresh water
tank refilling function (see “Fresh water tank
refilling function”) and for the parameters setting
(see “Setting”).
4) Button for system setting (see “Setting”).
5) General light control button (light groups “A” and
“B”).
6) Button to switch the pump on and off.
7) Awning light button; this light switches automati-
cally off when you start up the engine.
8) Button for “AUX” output power supply .
9) Sensor for activating the twilight function and
waking up the control panel with proximity system.
10) “B2” auxiliary battery status display.
11) Fresh water tank status display.
12) External temperature digital indicator.
13) Internal temperature digital indicator.
14) Clock digital display.
15) Date display.
16) It displays that the “+ key” is activated (the symbol
appears even when the panel is off).
17) It displays that the battery parallel is on when
engine is on (the symbol appears even when the
panel is off).
18) It displays that the engine battery recharging unit
is on.
19) It indicates that the 230 V power supply is
connected (the symbol appears even when the
panel is off).
20) It indicates the recharging through solar panel
(with a CBE solar regulator only).
21) It displays, with “+ key” inserted, that the 230V
mains is still connected. The alarm is signalled
even when the panel is switched off.
22) It displays the minimum voltage control device is
on.
23) It displays that the engine battery (B1) has run
down.
24) It displays that the auxiliary battery (B2) has run
down.
25) It displays that the fresh water tank or the
additional fresh water tank (optional) is empty.
26) It displays that the waste water tank is full.
Fresh water tank refilling function
This function is used during the fresh water tank
refilling, and shows the water level during refilling.
To activate this function, press for more than two
seconds on button (3) until the “water fill” screen
appears.
The control panel beeps in order to warn that tank is
getting filled: one short beep at 75% level, two short
beeps at 85% level a one long beep at 100% level.
Minimum voltage control (battery
protection)
The electronic battery protection device disconnects
the 12 V users when auxiliary battery reaches 10 V
and disables: pump, lights, awning light, RH output,
AUX output, 12 V sockets.
Symbol (22) is the visual alarm signal.
It is possible to connect all users for one more minute
by pressing the ON/OFF button (1).
The control panel automatically turns off with a
voltage lower than 9.5 V.
Users are automatically reconnected with a voltage
higher than 13.5 V.
This device doesn’t control the 12 V users connected
directly to the auxiliary battery B2.
10
15
11
12
13
14
16
21
17
22
18
23
19
24
20
25 26
3
4
1
2
5
6
8
7
9
Summary of Contents for Kosmo Compact 5
Page 6: ...USER GUIDE 6 TABLE OF CONTENTS...
Page 24: ...USER GUIDE 24 4 DOORS AND HATCHES...
Page 46: ...USER GUIDE 46 8 ELECTRIC SYSTEM KOSMO...
Page 50: ...USER GUIDE 50 9 CONTROL PANEL...
Page 56: ...USER GUIDE 56 11 REFRIGERATOR...
Page 72: ...USER GUIDE 72 14 WATER SYSTEM ECOVIP KREOS...
Page 90: ...USER GUIDE 90 18 SETTEES...
Page 96: ...USER GUIDE 96 19 NIGHT CONVERSION OPTIONAL...
Page 98: ...USER GUIDE 98 20 AL KO CHASSIS...
Page 100: ...USER GUIDE 100 21 GARAGE REAR STORAGE SPACE...
Page 108: ...USER GUIDE 108 23 MAINTENANCE...
Page 110: ...USER GUIDE 110 24 CUSTOMER SERVICE...
Page 111: ...111 USER GUIDE...