63
USER GUIDE
13 - HEATING SYSTEM
13.1 Truma heating system
The Truma heating system consists of a heater
with integrated boiler and provides for environment
heating and production of hot water.
Hot air distribution is guaranteed by suitably
positioned vents.
The boiler emptying operation can be either manual,
by means of the special switch located on the drain
valve, or automatic. The boiler empties automatically
when the internal temperature is close to 3 °C. To
facilitate emptying operations, leave at least a kitchen
or a washroom tap open (it is however recommended
to leave all of them open, to prevent water from
stagnating inside the taps themselves with conse-
quent damages caused by frost).
The control panel can be digital (CP Plus) or analogue
depending on the model and equipment.
CP Plus digital control panel
All the functions of the system can be programmed
by the Truma CP Plus control panel (a). To switch on,
operate, and switch off the system, as well as for all
the information concerning maintenance and safety,
carefully read the manual of the manufacturer, which
is provided together with the vehicle documentation.
For the correct operation of the heating system,
leave all the air vents open.
NOTE
When the heating is turned off and there is the
risk of freezing, the boiler empties automatically.
NOTE
In case of either automatic or manual emptying,
close the drain valve for later use.
NOTE
a
Always remember that in absence of electric
power supply the heating system does not work.
For this reason during the winter it is recom-
mended to check the auxiliary battery charge
frequently and, if connecting to 230 V power
supply is impossible, limit the use of the various
appliances to the minimum to ensure the battery
charge enough to operate the heating system.
WARNING
If gas supply is cut-off (for example when a
bottle is empty) the control panel might show the
following error codes 507, 516 or 517. In these
conditions, first of all restore gas supply (for
example replacing the empty gas bottle with a
new one), then operate the knob/button on the
control panel to clear the error (remember that
when you press the knob/button for the first time
only the panel back lighting might switch on and
the knob/button needs to be pressed again). If
you delete the error four times without having
restored the gas supply first, the control panel
locks for 15 minutes (the error code flashes on
the display). If the error code is displayed and the
control panel switches off/on, the control panel
will lock for 15 minutes (the error code flashes
on the display). When the control panel locks, no
operation is allowed: you need to wait till the end
of the lock period (the error code stops flashing)
before operating on the control panel again.
WARNING
Before departure it is mandatory to completely
empty the hot water boiler.
WARNING
Summary of Contents for Kosmo Compact 5
Page 6: ...USER GUIDE 6 TABLE OF CONTENTS...
Page 24: ...USER GUIDE 24 4 DOORS AND HATCHES...
Page 46: ...USER GUIDE 46 8 ELECTRIC SYSTEM KOSMO...
Page 50: ...USER GUIDE 50 9 CONTROL PANEL...
Page 56: ...USER GUIDE 56 11 REFRIGERATOR...
Page 72: ...USER GUIDE 72 14 WATER SYSTEM ECOVIP KREOS...
Page 90: ...USER GUIDE 90 18 SETTEES...
Page 96: ...USER GUIDE 96 19 NIGHT CONVERSION OPTIONAL...
Page 98: ...USER GUIDE 98 20 AL KO CHASSIS...
Page 100: ...USER GUIDE 100 21 GARAGE REAR STORAGE SPACE...
Page 108: ...USER GUIDE 108 23 MAINTENANCE...
Page 110: ...USER GUIDE 110 24 CUSTOMER SERVICE...
Page 111: ...111 USER GUIDE...