CONNECT THE FREE AIR VENTED DRAIN LINES
Draining
The water is drained off by gravity through a heat-resistant pipe
DN 50
(2”), maximum
length 2 m, installed at an angle of no less than 4°.Mean temperature of the drain water:
180°F/82°C.
It is imperative to fit a drain cup to ensure a minimum air drop of 1” (25 mm). between the
appliance’s plastic drain elbow and drain line.
A direct connection is not permissible.
WARNING
The drain line must be outside the perimeter of the oven. It is prohibited to reduce
the drain diameter.
DRAIN EXHAUST VENT
(DO NOT BLOCK)
SAFETY EXHAUST VENT
(DO NOT BLOCK)
INLET FOR
DESCALING SOLUTION
STEAM GENERATOR
43
90028771rev00
Max. 200 cm
Min. 4
1" (25,4 mm).
Figure 2-4. Recommended
Drain Layout