INSTALL AND CONNECT WATER SUPPLY LINES
Figure 2-7. Water Supply Lines water trattament system
a.
Apply pipe dope or teflon tape to any threaded connection
b.
When installing a water supply system without a water trattament system, we
recommends the plumbing layout illustrated in Figure 2-6.
•
Install a single water line from the main untreated cold water supply to the water
solenoid valve outside the for the condenser and the steam generator rinsing.
•
Install a single water line from the main softened cold/hot (max. 122 °F/50 °C) water
supply to the water solenoid valve outside the for the steam generator filling up and
humidifier.
c.
When installing a water supply system with a water trattament system, we recommends
the plumbing layout illustrated in Figure 2-7.
Install a single water line from the untreated main cold/hot (max. 122 °F/50 °C) water
supply to the water solenoid valve before the water trattament system.
• The water supply line from the water trattament system connects to the steam generator
fill and humidifier connection.
• The cold water supply to the condenser and steam generator rinsing connection can be
untreated
d.
Use 3/4” lines for the steam generator/humidifier,and condenser and
steam generator rinsing lines respectively.
If larger lines are used, a pressure regulator must be installed in the supply line to
maintain the pressure specified in step 4.
e.
Install a manual water valve between the main cold water supply line and the
Oven\Steamer lines.
f
. The National Sanitation Foundation (NSF) requires installation of a check-valve in all
supply lines in accordance with and as required by local plumbing codes.
The recommended locations for check valves are shown in the recommended plumbing
layouts.
g
. We recommends installing a 40-mesh water strainer at the locations shown in the
recommended plumbing layouts.
49
90028771rev00
STEAM GENERATOR
FILLING UP
HUMIDIFIER
WATER CONNECTION
ON DIMENSION
DIAGRAM
PRESSURE REDUCER
(IF REQUIRED)
STEAMERGARD
WATER TREATMENT
SYSTEM
CHECK VALVE
40-MESH STRAINER
AIR/WATER COLUMN
(IF REQUIRED)
MAIN WATER
SHUT-OFF VALVE
UNTREATED
MAIN COLD/HOT
MAX 122
ϒ
F/50
ϒ
C
WATER SUPPLY
Summary of Contents for Naboo Compact CBEN061
Page 2: ... 2 90028771rev00 ...
Page 20: ... 20 90028771rev00 INSTALLATION DIAGRAMS ...
Page 64: ... 64 90028771rev00 ...
Page 65: ... 65 90028771rev00 65 90028771rev00 ...
Page 66: ... 66 90028771rev00 66 90028771rev00 ...
Page 67: ......