H A R D W A R E I N T E R F A C E
1 8
Note: Leaving RTS disabled for too long can cause data loss once the transceiver’s 256 byte receive buffer fills up.
T e s t / 9 6 0 0 B a u d
When pulled logic Low before applying power or resetting, the transceiver’s serial interface is forced to a 9600, 8-N-1
(8 data bits, No parity, 1 stop bit). To exit, the transceiver must be reset or power-cycled with Test pin logic High. This
pin is used to recover transceivers from unknown baud rates only. It should not be used in normal operation. Instead
the transceiver Interface Baud Rate should be programmed to 9600 baud if that rate is desired for normal operation.
U P _ R e s e t
UP_Reset provides a direct connection to the reset pin on the AC4868-250 microprocessor and is used to force a soft
reset. For a valid reset, reset must be asserted High for a minimum of 11ms.
C o m m a n d / D a t a
When logic High, the transceiver interprets incoming OEM Host data as transmit data to be sent to other transceivers
and their OEM Hosts. When logic Low, the transceiver interprets OEM Host data as command data.
A D I n & D A O u t
AD In & DA Out can be used as a cost savings to replace Analog-to-Digital and Digital-to-Analog converter hardware.
Reading of this pin can be performed locally using the Read ADC command found in the On-the-Fly Control
Command Reference. DA Out is an unbuffered, high impedance output and MUST be buffered by the OEM Host
when used.
I n R a n g e
Reports logic Low when a Client transceiver is in range of a Server radio operating on the same RF Channel and
system ID. If a Client cannot hear a Server for the amount of time defined by Range Refresh, it will drive In_Range High
and enter search mode looking for a Server. When a server is detected, In_Range will be asserted Low. In_Range will
always report Low on Server transceivers.
E N G I N E E R ’ S T I P
Laird Technologies does not recommend permanently grounding the Forced_9600 pin. This
mode was intended for recovering transceivers from unknown settings and was not intended to
be used in real-time communications.