BT900-Sx Hardware Integration Guide
Intelligent BTv4.0 Dual Mode Module
Embedded Wireless Solutions Support Center:
http://ews-support.lairdtech.com
www.lairdtech.com/bluetooth
18
Americas: +1-800-492-2320
Europe: +44-1628-858-940
Hong Kong: +852 2923 0610
Enter VSP Command mode by externally pulling SIO_19 pin to GND at
power-up. OTA functionality is enabled through VSP Command mode.
4
P
OWER
C
ONSUMPTION
The BT900 module has User configurable clocking (40MHz, 20MHz, 4MHz), so user can reduce current
consumption at expense of speed. The default is 40MHz. Please note that when using the 4MHz clock, the
maximum supported board rate is 115200. This data was taken at VCC 3.3V and a temperature of 25
º
C.
4.1
Power Consumption across Clock Frequencies
Table 9: Power consumption at 40MHz, 20MHz, and 4 MHz
Parameter
At 40 MHz
At 20 MHz
At 4 MHz
Min
Typ
Max
Min
Typ
Max
Min
Typ
Max
Unit
Active Peak current (
TX only run peak current @TX pwr = +8
dBm
85
85
85
mA
TX only run peak current @TX pwr = +4
dBm
71
71
71
mA
TX only run peak current @TX pwr= 0 dBm
61
61
61
mA
TX only run peak current @TX pwr= -4 dBm
55
55
55
mA
TX only run peak current @TX pwr= -8 dBm
52
52
52
mA
TX only run peak current @TX pwr= -12
dBm
49
49
49
mA
TX only run peak current @TX pwr= -16
dBm
48
48
48
mA
TX only run peak current @TX pwr= -20
dBm
48
48
48
mA
RX only ‘peak’ current
TBD
TBD
TBD
Low Power Mode 1
Standby Doze (waitevent) (
9.4
5.9
2.7
mA
Low Power Mode 2 (
Deep Sleep (
233
233
233
uA
Classic BT Mode (
Inquiring Mode (AT+BTI)
18
18
34
mA
Wait for Connection or Discoverable
32
30
50
mA
BT900 Master Role (connection ACL)
(
Connecting Mode (ATDxxx)
31
28
53
mA
Connected Mode (No Data Transfer)
31
28
50
mA
Connected Mode (Max Data Transfer)
40
31
mA
BT900 Slave Role (connection ACL) (Note 5)
Connecting Mode (ATDxxx)
33
33
mA
Connected Mode (No Data Transfer)
16
12
mA
Connected Mode (Max Data Transfer)
31
23
mA
Inquiring (
Scan interval: 640ms, Scan Window: 320ms
18
18
mA
Scan interval 1920ms,
Scan Window 960ms
18
11
mA
BLE Mode