VERVIEW
This guide is to aid more rapid development of embedded applications using the Pinnacle
TM
100 modem using the Hosted-
Mode firmware. This guide will describe the setup and operation of eDRX and PSM, as well as, providing current
measurements of the modem, for both LTE Cat-M1 and Cat-NB1 with the use of a R&S CMW500 and a Amarisoft Callbox
mini.
•
PSM is intended for applications that seldom send data (once a day, for instance), and does not need to be reachable
or reachable with long latency (several hours, for instance).
•
eDRX is intended for applications that need to be reachable but tolerate latency in an order of magnitude of 10
seconds or more.
2
M
EASUREMENT
S
ETUP
&
R
EQUIREMENTS
2.1
Reference Material
•
AirPrime_HL7800_Low_Power_Modes_Application_Note_Rev2_0.pdf
•
AirPrime_HL78xx_AT_Commands_Interface_Guide_Rev9_3.pdf
•
CS-GUIDE-PINNACLE-100-DVK HW v1_0.pdf
•
•
CS-GUIDE-ATInterface-Pinnacle-100-Module v1_11.pdf
The AirPrime HL7800 provides advanced and efficient low power modes in addition to 3GPP advanced power saving features
like PSM (Power Saving Mode) and eDRX (extended DRX).
This document provides a detailed description of the AirPrime
HL7800’s low power modes while it is configured in PSM or
eDRX.
2.2
UwTerminalX
In this document, UwTerminalX, is used to communicate with the Host UART of the Pinnacle
TM
100 modem, and can be
downloaded by visting the Following link:
https://github.com/LairdCP/UwTerminalX
2.3
R&S CMW500 Block Diagram
6 dB Attenuator
JFW 50HF-006 SMA
Communica ti ons Test Set
On/ Off
------
- -- -- -- -
0
.
-
1
2
3
4
5
6
7
8
9
/ \
\ /
RF OUT
RF IN /OUT
------
------
------
------
------
------
------
- -- -- -- --
2 U x ½ wi d th S o ft F ra me
S tac ka b le
( p
l ace over ins tr ument, t hen Send t o Back)
12.34 56
1.234 56
V1
On/ Off
7
8
9
4
5
6
1
2
3
.
0
-
< >
+V2
Gnd
DC P owe r Sup p ly
Vol ts
Am ps
Com
-V3
+V1
Pinnacle
TM
100
On Pinnacle DVK
LTE U.FL CON1
SMA to U.FL Plug
HIROSE HRMJ-
U.FLP(40)
Between Series Adapter
SMA to SMA
RT Ang
Adapter
Workhorse
WHU18-3636-036
RF Cable
SMA Female
to N Male
Adapter
KEYSITE N6705C
w/ N6781A option
Setup as Current Meter
*Replace J4 Jumper with
power supply leads
R&S CMW500
LTE-M1 or NB1 Signaling
USB VCP
115200, N, 8, 1, RTS/CRTS
Figure 1: R&S CMW500 Test Configuration