RM024 User Manual
Version 2.3
Americas: +1-800-492-2320 Option 2
Europe: +44-1628-858-940
Hong Kong: +852-2923-0610
www.lairdtech.com/wireless
6
CONN-GUIDE-RAMP24-0413
C
ERTIFICATIONS
FCC Part 15.247
KQL-RM024
Industry Canada (IC)
2268C-RM024
CE
Yes, RM024-x50-x versions
RoHS
Yes
Japan (TELEC)
4
Yes
Brazil (Anatel)
5
None
1.
Maximum Output power stated, step measurements for power could vary by +/- 2.0 dBm.
2.
Sleep currents are estimated
3.
Range distances are estimated, measurements were taken at 4.1 miles with 5 dBi antenna for FCC
module
4.
See
Regulatory Information
in this manual
5.
Contact your sales representative for more details.
Pin Definitions
Table 2: Pin Definitions
SMT
Pin
Pluggable Pin
Type
Signal Name
Functions
1
7
O
GIO_0
Generic Output / Hop_Frame
2
6
O
GIO_1
Generic Output
3
8
DNC
Do Not Connect
4
17
O
GIO_2
RS485 Driver Enable
5
19
O
GIO_3
PWM Output
6
3
I
RXD
Asynchronous serial data input to transceiver
7
2
O
TXD
Asynchronous serial data output from transceiver
8
10
GND
GND
Signal Ground
9
1
PWR
Vcc
2.3 – 3.6 V ±50 mV ripple (must be connected)
10
-
PWR
Vpa
2.3 - 3.6 V ±5 0mV ripple (must be connected)
11
-
GND
GND
Signal Ground
12
9
I
Force 9600
/Sleep Interrupt
Force 9600 – When pulled logic Low and then
applying power or resetting, the transceiver’s
serial interface is forced to a 9600, 8-N-1 rate.
Sleep Interrupt- When taken low this pin will
wake the radio from sleep
Note: Because this mode disables some modes
of operation, it should not be
permanently pulled Low during normal
operation.
13
14
I
GIO_4
Generic Input
14
5
I
µP_Reset
RESET – Controlled by the RM024 for power-on
reset if left unconnected. After a stable power-on
reset, a logic Low pulse will reset the transceiver.
15
11
I
CMD/Data
When logic Low, the transceiver interprets
incoming OEM Host data as command data.
When logic High, the transceiver interprets OEM
Host data as transmit data.
Downloaded from
Downloaded from
Downloaded from
Downloaded from
Downloaded from
Downloaded from