https://www.lairdconnect.com/iot-devices/iot-
sensors/sentrius-bt7x0-tracker-multi-sensor
11
© Copyright 2020 Laird Connectivity, Inc.
All Rights Reserved
Americas: +1-800-492-2320
Europe: +44-1628-858-940
Hong Kong: +852 2923 0610
Field Name
Size (Bytes)
Data Type
Description
0x50
– IG60
Battery Voltage
1
uint8
Battery voltage divided by 16 (in millivolts)
Firmware Version
1
uint8
4 MSB bits: Major version, 4 LSB bits: Minor version
Firmware Build
1
uint8
Build version
The tracer has several parameters that can be used to tailor it for each use case.
The table below lists the common parameters that can be adjusted by the user based on the use case the tracer is being applied
to. These parameters can be updated using the BT710 mobile application.
Parameter Name
Default Value
Description
General Settings
Tx Power
+8 dBm
Transmit power of BLE radio (-20dBm to +8dBm)
Low Battery Threshold
2600 mV
Voltage level triggering a low battery indication
Distance Filter
1
RSSI filter selection (0: none, 1: average)
Antenna Option
Ant 1 TX, Both
RX
Select how antennas are used for transmit (TX) and receive (RX)
Active Scan Interval
10 sec
Seconds between scan/discovery events (Active Mode)
Active Scan Duration
2 sec
How long to scan for/discover nearby tracers (Active Mode)
Active Ad Interval
250 ms
Milliseconds between advertisement TX events (Active Mode)
Active Motion Timeout
300000 ms
Milliseconds of no motion to trigger “Non-Active Mode” from “Active Mode”
Non-Active Scan Interval
120 sec
Seconds between scan/discovery events (Non-Active Mode)
Non-Active Scan Duration
2 sec
How long to scan for/discover nearby tracers (Non-Active Mode)
Non-Active Ad Interval
500 ms
Milliseconds between advertisement TX events (Non-Active Mode)
Non-Active Motion Timeout
600000 ms
Milliseconds of no motion to trigger “Power-Save Mode” from “Non-Active
Mode”
Non-Active Motion Detect
500 ms
Milliseconds of motion to wake from
“Non-Active Mode”
Power Save Scan Interval
3600 sec
Seconds between scan/discoveryevents (Power-Save Mode)
Power Save Scan Duration
1 sec
How long to scan for/discover nearby tracers (Power-Save Mode)
Power Save Ad Interval
1000 ms
Milliseconds between advertisement TX events (Power-Save Mode)
Power Save Motion Detect
500 ms
Milliseconds of motion to wake from “Power-Save Mode”
Logging
Profile
0
User assignable value for categorizing tracer types
Network ID
65535
Network identifier for grouping tracers and gateways
Log Interval
2 min
How often data log is available for download (if present). Datalogging and data
collection is disabled if this value is set to 0.
Contact Period
86400 sec
Period being monitored for a contact event
Discovery Duration
300 sec
Time a tracer must be observed before logging to storage
Tracking Duration
1800 sec
Maximum log time for each tracer per contact period