background image

 

1.  About this Manual 

This Operational Manual addresses the needs of the user of the unit. Its intention is to allow the safe 

operation of the unit. Thus, it should be read carefully and be kept in a space accessible for the users 

of the unit at any time. 
All chapters of this Operation Manual can be read independently and thus can be used for look-up 

purposes. 

1.1 Terms of Guarantee 

General sale and delivery terms of LAIRD apply. The buyer accepts these terms, at the latest when 

signing the contract of purchase. 
The particular terms of guarantee and duration of guarantee of the unit in question can be taken from 

the contract documents as well as from the order confirmation. 
Warranty claims and liability are excluded in case of one of the following situations: 

  Use of the unit in an unintended way 

  Inaccurate installation, putting into service, operation, repair or maintenance of the product by 

people that are not fully authorized 

  Use of the product despite of defect, wrongly implemented or non-functional safety devices or 

protective gear 

  Unauthorized or forbidden modifications by the user concerning the electrical equipment of the 

unit  

  Unauthorized or forbidden modifications by the user concerning the mechanical structure of the 

unit  

  Unauthorized or forbidden modifications by the user concerning the operating parameters 

  Use of unauthorized tools 

  Use of unauthorized operating supplies 

  Exceedance of mandatory maintenance intervals 

  Cases of disaster caused by foreign matter influence or act of nature beyond control 

PLEASE NOTE 

Any form of unintended use of the unit and any structural change caused by the user without prior 

authorization in written form by LAIRD will lead to the termination of warranty as well the termination of the 

declaration of conformation and will free LAIRD from product liability. This concern includes safety devices 

as well. 

In case of authorized changes or when adding optional equipment, it is the sole responsibility of the 

customer to assure the accurate implementation of the safety devices required. 

 

 

Summary of Contents for WL 5000

Page 1: ...WL 5000 Specification and User Manual...

Page 2: ...e without notice Laird assumes no responsibility and disclaims all liability for losses or damages resulting from use of or reliance on this information All Laird products are sold subject to the Lair...

Page 3: ......

Page 4: ...ct Description 13 4 1 Description 13 4 2 Non Conformity with the Intended Use 13 4 3 Technical data 14 4 3 1 Physical dimensions 14 4 3 2 Performance data 14 4 3 3 Environmental specifications 14 4 3...

Page 5: ...5 8 Removal for Service 21 9 Wear Parts and Spare Parts 22...

Page 6: ...sion History Date Index Reason for Change Name Page 13 Apr 20 1 0 First version 22 May 20 2 0 New template Page no Updated A Olsson 10 MAR 2021 2 1 Corrected P N A Kim 06 OCT 2021 2 2 New template A C...

Page 7: ...uthorized Use of the product despite of defect wrongly implemented or non functional safety devices or protective gear Unauthorized or forbidden modifications by the user concerning the electrical equ...

Page 8: ...e use the contact information given below Always communicate the following Your name and address Name of contact at your address Product data as on identification plate Type of unit serial number and...

Page 9: ...roperty 2 2 Safety Symbols In this Operation Manual concrete safety instructions are given in order to point out unpreventable residual risks when operating the unit These risks include danger for Hum...

Page 10: ...concerning the unit should be reported to the responsible person Stick to accident prevention regulations as well as any regional regulations 2 3 2 Hints Regarding the Electrical Equipment DANGER Dan...

Page 11: ...ntally conscious behavior Environmentally hazardous substances must not get into the soil or into the drains They should be kept in appropriate containers Environmentally hazardous substances must be...

Page 12: ...ety equipment must be accessible at all times 2 4 1 Guards Direct access to hazardous parts or areas of the unit is restricted by the unit cover The cover may only be removed for maintenance or repair...

Page 13: ...n not be granted When using the unit in a way not compliant with the intended use hazardous situations may occur Operation of the unit is not permitted under the following conditions The unit is used...

Page 14: ...V 10 50 60 Hz Current consumption 2 6 A Noise level 63 dB A 50 Hz 67 dB A 60 Hz at 1 m distance in any direction Table 2 Performance data 3 3 3 Environmental specifications Operating temperature 10 C...

Page 15: ...d corrosion damage may result and are not covered by manufacturer s liability The unit is only authorized for use in indoor environments The unit must not be stored or operated in aggressive humid env...

Page 16: ...ons on page 9 4 2 Setting to Work 4 2 1 Connecting the unit electrically DANGER Electrical danger Work on electrical installations may be carried out by trained and authorized electricians only Switch...

Page 17: ...hoses Open lid Fill cooling unit with water about 5 0 l CAUTION The water level must be always above fins otherwise reduced cooling capacity Let the cooling unit run for about 10 minutes to deaerate t...

Page 18: ...available direct the air against the inside of the heat exchanger 4 Mount cover 5 2 Pump About every 3 months check the filter of the pump for clean condition in case of polluted water more often CAUT...

Page 19: ...r abrasive cleaning agents corrosion may occur as result of a damaged paint film For cleaning the device casing only use mild cleaning agents e g dish washing detergents Use clean and lint free cloth...

Page 20: ...20 6 Repair PLEASE NOTE Do not carry out any repair work on the unit Send the unit back to the LAIRD service department for contact see page 7...

Page 21: ...ore starting any service work disconnect the cooling unit from the mains Remove electrical connections Remove hoses Remove cap of the drain hole and purge coolant collect with suitable vessel Mount it...

Page 22: ...e of damages caused by the use of spare parts made by manufacturers other than LAIRD PLEASE NOTE Identification data concerning the unit and spare parts The type of unit and the article number can be...

Page 23: ...3 O Ring for cap Not available 4 Thermal switch 2032 00 5 Lid 2075 00 6 Motor with coupling 2001 00 7 Flexible coupling 2038 00 8 Fan 2029 00 9 Capacitor for fan 2088 00 10 Filter 2081 00 11 Flow swit...

Reviews: