background image

LakeAir ELECTRONIC AIR CLEANERS 

7 YEAR LIMITED WARRANTY 

The complete LakeAir Electron Air 
Cleaner is warranted by LakeAir Interna-
tional, Inc. to the original purchaser to be 
free from defects in material and work-
manship under normal use and service for 
a period of one year from the date of pur-
chase.  In addition, LakeAir International, 
Inc. warrants the power supply module 
and transformer in the LakeAir Electronic 
Air Cleaner for an additional six (6) years 
or a total of seven (7) years from the date 
of purchase to the original purchaser.  
LakeAir’s liability is to be limited to re-
pairing or replacing such products during 
the warranty period at its option, provid-
ing the product is sent prepaid to LakeAir 
International, Inc. or an Authorized Ser-
vice Center and is deemed to the satisfac-
tion of LakeAir International, Inc. to be 
defective in any part or portion. 

This warranty is in lieu of any other war-
ranty expressed or implied and of all other 
obligations or liabilities in connection 
with the sale of the described LakeAir 
Electronic Air Cleaner.  In no case will 
any claim for consequential damages or 
labor expenses be allowed.  This warranty 
does not apply to a LakeAir Electronic 
Air Cleaner or any part thereof which has 
not been operated in accordance with the 
operating instructions herein contained; 
where components or other accessories 
not compatible with the LakeAir Elec-
tronic Air Cleaner have been used or at-
tached to it; which has been subject to 
accident, unauthorized alteration, abuse, 
damage by flood, fire or acts of nature. 

User’s Responsibility 

Please Note:  Your warranty is subject to 
user responsibility.  Some items and some 
conditions resulting from causese other 
than manufacturing defects are the re-
sponsibility of the user of the LakeAir 
Electronic Air Cleaner and are not cov-
ered by the Warranty.  These are: 

1. To operate and maintain according to
instructions.
2. Periodic checking and cleaning of unit.
Failure to clean will void warranty.
3. Proper use of controls must be main-
tained or warranty will be voided.
4. Damage to unit from unsatisfactory
operation because of blowing fuses, in-
adequate electrical service or operation on
power supply other than that indicated on
the rating plate, or incorrect electrical
protection devices used.
5. Damage occurring during transporta-
tion or resulting from improper handling.
6. Damage due to accident or resulting
from alteration or tampering.
7. Misapplication of product.

RK  Ventures

  inc. 

1509  Rapids  Drive 

Racine, WI  53404 

12 

Summary of Contents for LA2000

Page 1: ...OPERATING AND SERVICE INSTRUCTIONS RK Ventures Inc www lakeair com LA2000 LA2000 OC ...

Page 2: ...Electronic Air Cleaners I I I Operating Instructions I V Cleaning Electronic Cell s and Filter A Removal of Electronic Cell s Prefilter Screen and Carbon Afterfilter B Cleaning the Prefilter Screen C Cleaning the Carbon Filter D Cleaning the Electronic Cell s V Repa an ir Main d tenance A Owner s Checklist and Return Procedure B Trouble Shooting Electronic Air Cleaners C Parts List V I Schematic D...

Page 3: ... collector plates and trapped there just like a magnet attracts and collects iron fillings 3 The optional ACTIVATED CARBON FILTER removes odors and freshens the air 4 The cleaned and purified air is now dis charged to recirculate through your establish ment B SPECIFICATIONS Input Voltages Model LA2000 Model LA 2000 OC 120 VAC 60 Hz 6 Amps Model LA 1402S 120 VAC 60 Hz 6 Amps Model LA 2002S Capacity...

Page 4: ...feet of air in the area to be cleaned and then use a figure of 8 air changes hour in that area for average cleaning and 16 air changes per hour for very polluted or smoke filled conditions You should remember that the slower the air passes over the surface of the air cleaner the more efficiently the unit will operate Therefore when calculating the number of units needed take into account air flow ...

Page 5: ...eaner 2 Make sure you have correct lengths of chain and that it is capable of sustaining the weight of the unit Standard hardware item link chain with a working load of at least 100 lbs Also make sure you have mounting lag screws or equivalent fasteners to at tach the chain to the ceiling beams or studs In some instances it may be necessary to construct a mounting frame to properly suspend the uni...

Page 6: ...c cell must be inspected frequently and the collected dirt removed regularly to prevent excess accumulation which may result in risk of flashover and fire damage Inspect electronic cells and filters every week for the first month or two to determine your required cleaning schedule Use the following as a guide for your establishment Cocktail Lounge Conference Room Restaurant Every week if run daily...

Page 7: ...hwasher using a detergent marked Safe for Aluminum Allow to dry thoroughly b Soaking Method 1 Use a washing container large enough to hold the cells such as a laundry tub or trash container 2 Fill container with hot water 3 Dissolve 1 1 1 2 cups dishwasher detergent or use a detergent marked Safe for Aluminum 4 Soak cell for 15 minutes agitate and remove 5 Rinse cell with a fine spray of water 6 S...

Page 8: ...motor oil only SAE 20 V REPAIR AND MAINTENANCE A OWNER S CHECKLIST RETURN PROCEDURE Before attempting any repairs on your Electronic Air Cleaner check the following items first 1 Chec fu k se 2 Check for electrical power to unit 3 Check that the electronic cell prefilter screen and carbon filter are CLEAN dry and properly installed in the Air Cleaner Repair work should only be performed by a train...

Page 9: ... indicated number of test points INDICATOR LIGHT DOES NOT WORK 1 Check fuse 2 Plug power supply into the proper receptacle 3 Measure line voltage at power source 120V depending on unit 4 Replace light COLLECTOR CELL MALFUNCTION 1 Remove electronic cell and inspect for bent collector plates Make sure cell is thoroughly clean and dry 2 3 Return electronic cell to air cleaner cabinet Do not install p...

Page 10: ...MPLETE CELL ASSEMBLY LA2000 COMPLETE CELL ASSEMBLY LEFT LA2000 COMPLETE CELL ASSEMBLY RIGHT FAN BLADE LA2000 LA2000 OC 120V TRANSFORME w TERMINALS R 230V TRANSFORMER 120V MOTO TOR 230V MOTOR CORD ASSEMBLY MICRO SWITCH ASSEMBLY VOLTAGE DOUBLER ROCKER SWITCH LIGHT 120V LIGHT 230V FUSE HOLDER 5 AMP FUSE 1 REQUIRED 1 SPARE IN FUSE HOLDER PREFILTER SCREEN EYEBOLT KIT 4 PCS ION WIRES w SPRINGS S HOOKS 6...

Page 11: ...ELECTRICAL SCHEMATIC MODEL LA2000 LA2000 OC 11 ...

Page 12: ...nty does not apply to a LakeAir Electronic Air Cleaner or any part thereof which has not been operated in accordance with the operating instructions herein contained where components or other accessories not compatible with the LakeAir Elec tronic Air Cleaner have been used or at tached to it which has been subject to accident unauthorized alteration abuse damage by flood fire or acts of nature Us...