Locate Electronic Air Cleaners consistent with
existing air circulation in the room so that the
heating and air conditioning systems are comple-
mented by the air cleaners.
C.
MOUNTING YOUR LakeAir MODEL LA
2000
OR 2000
-OC
ELECTRONIC AIR
CLEANER
LakeAir provides a
8
’ cord with every air cleaner, but it is the responsibility of the purchaser
to provide adequate outlet which meets local codes. An approved extension cord may be
used if it meets local and national codes.
Both the LA
2000
and LA2000
-OC
are designed with 4 mounting holes on the top and the
bottom of the unit. LakeAir provides eye bolts with the units so they may be hung by chains
from supporting beams on the ceiling. If you choose the optional wall mount for the
LA
200
00 or LA2000
-OC
, see the instruction sheet included with the Model 10009 Wall
Mount. To mount using the included eye bolts, follow the instructions below. The unit may
be hung so the air flow is from the left to the right, or from the right to the left depending on
the needs of the customer.
1. Choose an area which compliments the rest of
the air flow in the room before you mount the air
cleaner.
2. Make sure you have correct lengths of chain, and
that it is capable of sustaining the weight of the unit.
Standard hardware item, link chain with a working
load of at least 100 lbs. Also make sure you have
mounting lag screws or equivalent fasteners to at-
tach the chain to the ceiling beams or studs. In
some instances, it may be necessary to construct a
mounting frame to properly suspend the unit.
3. Locate the ceiling studs or beams and attach the
correctly sized chain. Chain length should be such
that it will not allow the LA
2000
or LA
2000-OC
to
have a floor to bottom height which would pose a
hazard to room occupants. LakeAir recommends a
minimum height of eight feet from floor to bottom
when chain hung.
Chain
Mount
Optional
Wall
Mount
Air cleaners must be mounted to strong
structural parts of the ceiling with adequate
head clearance, and should be a minimum
of 10 feet from air intake or exit ductwork
B.
PROPER LOCATION OF MODEL LA
2000
OR LA2000
-OC
ELECTRONIC
AIR
CLEANER:
*Air cleaner #1 pulls air from heavy con-
tamination area.
*Air cleaners #2 & #3 maintain general
circulation.
*Air cleaner #4 pulls air from above.
*All air cleaners aid in setting up definite
air circulation pattern.
LA air pattern should aid, not oppose any
pre-existing air flow pattern due to heating
air conditioning, exhaust and inlet vents.