background image

Locate Electronic Air Cleaners consistent with 
existing air circulation in the room so that the  
heating and air conditioning systems are comple-
mented by the air cleaners. 

C.

 

MOUNTING YOUR LakeAir MODEL LA

2000

 OR 2000

-OC

 ELECTRONIC AIR

 

CLEANER

LakeAir provides a 

8

’ cord with every air cleaner, but it is the responsibility of the purchaser

 

to provide adequate outlet which meets local codes.  An approved extension cord may be

 

used if it meets local and national codes.

Both the LA

2000

 and LA2000

-OC

 are designed with 4 mounting holes on the top and the  

bottom of the unit.  LakeAir provides eye bolts with the units so they may be hung by chains 
from supporting beams on the ceiling.  If you choose the optional wall mount for the  
LA

200

00 or LA2000

-OC

, see the instruction sheet included with the Model 10009 Wall 

Mount.  To mount using the included eye bolts, follow the instructions below.  The unit may 
be hung so the air flow is from the left to the right, or from the right to the left depending on 
the needs of the customer. 

1. Choose an area which compliments the rest of
the air flow in the room before you mount the air
cleaner.
2. Make sure you have correct lengths of chain, and
that it is capable of sustaining the weight of the unit.
Standard hardware item, link chain with a working
load of at least 100 lbs.  Also make sure you have
mounting lag screws or equivalent fasteners to at-
tach the chain to the ceiling beams or studs.  In
some instances, it may be necessary to construct a
mounting frame to properly suspend the unit.
3. Locate the ceiling studs or beams and attach the
correctly sized chain.  Chain length should be such 
that it will not allow the LA

2000

 or LA

2000-OC

 to 

have a floor to bottom height which would pose a 
hazard to room occupants.  LakeAir recommends a 
minimum height of eight feet from floor to bottom 
when chain hung. 

Chain 
Mount 

Optional 
Wall  
Mount 

Air cleaners must be mounted to strong 
structural parts of the ceiling with adequate 
head clearance, and should be a minimum 
of 10 feet from air intake or exit ductwork 

B.

 

PROPER LOCATION OF MODEL LA

2000 

OR LA2000

-OC

 ELECTRONIC 

AIR

 

CLEANER:

*Air cleaner #1 pulls air from heavy con-
tamination area.
*Air cleaners #2 & #3 maintain general
circulation.
*Air cleaner #4 pulls air from above.
*All air cleaners aid in setting up definite
air circulation pattern.

LA air pattern should aid, not oppose any 
pre-existing air flow pattern due to heating 
air conditioning, exhaust and inlet vents. 

Summary of Contents for LA2000

Page 1: ...OPERATING AND SERVICE INSTRUCTIONS RK Ventures Inc www lakeair com LA2000 LA2000 OC ...

Page 2: ...Electronic Air Cleaners I I I Operating Instructions I V Cleaning Electronic Cell s and Filter A Removal of Electronic Cell s Prefilter Screen and Carbon Afterfilter B Cleaning the Prefilter Screen C Cleaning the Carbon Filter D Cleaning the Electronic Cell s V Repa an ir Main d tenance A Owner s Checklist and Return Procedure B Trouble Shooting Electronic Air Cleaners C Parts List V I Schematic D...

Page 3: ... collector plates and trapped there just like a magnet attracts and collects iron fillings 3 The optional ACTIVATED CARBON FILTER removes odors and freshens the air 4 The cleaned and purified air is now dis charged to recirculate through your establish ment B SPECIFICATIONS Input Voltages Model LA2000 Model LA 2000 OC 120 VAC 60 Hz 6 Amps Model LA 1402S 120 VAC 60 Hz 6 Amps Model LA 2002S Capacity...

Page 4: ...feet of air in the area to be cleaned and then use a figure of 8 air changes hour in that area for average cleaning and 16 air changes per hour for very polluted or smoke filled conditions You should remember that the slower the air passes over the surface of the air cleaner the more efficiently the unit will operate Therefore when calculating the number of units needed take into account air flow ...

Page 5: ...eaner 2 Make sure you have correct lengths of chain and that it is capable of sustaining the weight of the unit Standard hardware item link chain with a working load of at least 100 lbs Also make sure you have mounting lag screws or equivalent fasteners to at tach the chain to the ceiling beams or studs In some instances it may be necessary to construct a mounting frame to properly suspend the uni...

Page 6: ...c cell must be inspected frequently and the collected dirt removed regularly to prevent excess accumulation which may result in risk of flashover and fire damage Inspect electronic cells and filters every week for the first month or two to determine your required cleaning schedule Use the following as a guide for your establishment Cocktail Lounge Conference Room Restaurant Every week if run daily...

Page 7: ...hwasher using a detergent marked Safe for Aluminum Allow to dry thoroughly b Soaking Method 1 Use a washing container large enough to hold the cells such as a laundry tub or trash container 2 Fill container with hot water 3 Dissolve 1 1 1 2 cups dishwasher detergent or use a detergent marked Safe for Aluminum 4 Soak cell for 15 minutes agitate and remove 5 Rinse cell with a fine spray of water 6 S...

Page 8: ...motor oil only SAE 20 V REPAIR AND MAINTENANCE A OWNER S CHECKLIST RETURN PROCEDURE Before attempting any repairs on your Electronic Air Cleaner check the following items first 1 Chec fu k se 2 Check for electrical power to unit 3 Check that the electronic cell prefilter screen and carbon filter are CLEAN dry and properly installed in the Air Cleaner Repair work should only be performed by a train...

Page 9: ... indicated number of test points INDICATOR LIGHT DOES NOT WORK 1 Check fuse 2 Plug power supply into the proper receptacle 3 Measure line voltage at power source 120V depending on unit 4 Replace light COLLECTOR CELL MALFUNCTION 1 Remove electronic cell and inspect for bent collector plates Make sure cell is thoroughly clean and dry 2 3 Return electronic cell to air cleaner cabinet Do not install p...

Page 10: ...MPLETE CELL ASSEMBLY LA2000 COMPLETE CELL ASSEMBLY LEFT LA2000 COMPLETE CELL ASSEMBLY RIGHT FAN BLADE LA2000 LA2000 OC 120V TRANSFORME w TERMINALS R 230V TRANSFORMER 120V MOTO TOR 230V MOTOR CORD ASSEMBLY MICRO SWITCH ASSEMBLY VOLTAGE DOUBLER ROCKER SWITCH LIGHT 120V LIGHT 230V FUSE HOLDER 5 AMP FUSE 1 REQUIRED 1 SPARE IN FUSE HOLDER PREFILTER SCREEN EYEBOLT KIT 4 PCS ION WIRES w SPRINGS S HOOKS 6...

Page 11: ...ELECTRICAL SCHEMATIC MODEL LA2000 LA2000 OC 11 ...

Page 12: ...nty does not apply to a LakeAir Electronic Air Cleaner or any part thereof which has not been operated in accordance with the operating instructions herein contained where components or other accessories not compatible with the LakeAir Elec tronic Air Cleaner have been used or at tached to it which has been subject to accident unauthorized alteration abuse damage by flood fire or acts of nature Us...

Reviews: