www.TWISTIICLEAN.com
Fig A
Fig B
Fig C
Installation In 7 Easy Steps
Optional Accessories
Sun Shield For Outdoor
Installations
Black neoprene woven cover, slips over
bowl to prevent growth of algae and other
organics.
Purge Exit
Hose
Model Size
T2C-075 (¾")
T2C-100 (1")
T2C-150 (1-½")
SUN SHIELD
1. Remove the TWIST
II
CLEAN from its box. Check to make sure
the box also contains a small dispenser of Teflon tape and two
slip/threaded adapters for use if needed.
2. Be sure the clear bowl is securely tightened (hand tighten only).
The unit is shipped with the bowl loose. Lift the red safety latch
and rotate the top handle a few times to make sure it will rotate
1/4
clockwise turn.
3. Prepare the piping manifold to install TWIST
II
CLEAN. Select
the best fittings for your installation, using slip or threaded
fittings as desired. Notice the direction of water flow through the
unit -- a flow direction arrow is molded into the side of the unit.
(Fig A).
4. Use proper PVC solvents and follow gluing instructions on
solvent container. Do not spill solvent on any part of the
TWIST
II
CLEAN unit.
5. Mounting eyelets provide for a more stable installation (Fig B).
Stabilizer bolts are recommended for long term stability of your
TWIST
II
CLEAN. Use ⅜" Hex Lag Screws plus washers and
PVC pipe to connect to a secure surface. These parts are NOT
supplied with your TWIST
II
CLEAN.
6. Once installed, test by turning water supply on slowly, allowing
water to feed through the unit. Check for leaks. After lifting
the safety latch, twist the top handle with a ¼ clockwise turn to
re-direct the flow for cleaning. This should lift the screen element
inside the bowl and release flush water through the purge exit at
the bottom of the unit. Twist the handle back to its “run” position,
lower the safety latch and check for leaks.
7. Attach a flush drain hose (if necessary) to direct the purged
particle matter and excess water to a drain or other desired area
for discharge (Fig C).
Just TWIS
T
to CLEAN
TWIST
II
CLEAN removes sand and organics as the water passes through the filter element.
Periodic cleaning is necessary to optimize filter performance, reduce the pressure loss and
prolong the product life. When the filter element
looks like it is filled with debris, it should be cleaned.
Just a gentle 1/4 clockwise TWIST of the top
handle begins the patented reverse flushing action.
In just a few seconds, all debris are backwashed
off the filter element and flushed out the bottom
of the Purge Exit port. Be sure to raise the safety
latch before twisting the handle and lower it after
flushing.
Using Your TWIST
II
CLEAN
Normal Mode
Flush Cleaning
Mode
Water Flow Direction
TWIST
II
CLEAN Exploded View
and Spare Parts
Safety Latch
Stabilizer Bolts
(not provided by LAKOS)
Gasket/Housing
O-Ring Kit
131729 (T2C-075 and 100)
132237 (T2C-150)
Filter Element Kit
131730 (30 Mesh)
131731 (60 Mesh)
131732 (100 Mesh)
131733 (140 Mesh)
132232 (30 Mesh)
132233 (60 Mesh)
132234 (100 Mesh)
132235 (140 Mesh)
Pin & O-Ring Kit
132093 (T2C-075-100)
Bowl & O-Ring Kit
131728 (T2C-075-100)
132236 (T2C-150)
O-Ring Kit
132346 (T2C-150)
T2C-
075-100
T2C-150
Sun Shield
Part Number
131355
132240