83-507-013 Rev. A
65
Refer to Tables 7-10 to 7-13 for details of the Enable and Event registers.
1. Fault Enable Register
The Fault Enable Register is set to the enable faults SRQs.
Table 7-10: Fault Enable Register
BIT
Enable
bit name
Fault symbol
Bit Set condition
Bit reset condition
0 (LSB) Spare bit
SPARE
1 AC
Fail
AC
2 Over
Temperature
OTP
3 Foldback
FOLD
4 Over
Voltage OVP
5 Shut
Off
SO
6 Output
Off
OFF
7(MSB) Enable
ENA
User command:
“FENA nn” where
nn is hexadecimal
User command: “FENA nn”
where nn is hexadecimal (if
nn=”00”, no fault SRQs will
be generated).
2. Fault Event Register
The Fault Event will set a bit if a condition occurs and it is Enabled. The register is cleared when FEVE?,
CLS or RST commands are received.
Table 7-11: Fault Event Register
BIT
Enable
bit name
Fault symbol
Bit Set condition
Bit reset condition
0 (LSB) Spare bit
SPARE
1 AC
Fail
AC
2 Over
Temperature
OTP
3 Foldback
FOLD
4 Over
Voltage OVP
5 Shut
Off
SO
6 Output
Off
OFF
7(MSB) Enable
ENA
Fault condition
occurs and it is
enabled.
The fault can set a
bit, but when the
fault clears the bit
remains set.
Entire Event Register is
cleared when user sends
“FEVE?” command to read
the register.
“CLS” and power-up also
clear the Fault Event Regis-
ter. (The Fault Event Regis-
ter is not cleared by RST)