CONVERSION 55 - 70
For models 55 and 70 it is sufficient to replace the diffuser ring as indicated in the figure.
Loosen screws
A
, remove the diffuser ring
B
and replace it by the ring type
C
, which is different for the lower
quantity of gas outlet holes.
B
A
C
CONVERSION FOR OPERATION WITH DIFFERENT TYPES OF GAS
The burners are delivered equipped with a head set suitable to operate with only one type of gas (natural gas
or B/P).
Should you need to adapt the burner to a different type of gas (ex. from NATURAL GAS to B/P), you should
purchase the suitable gas conversion kit.
CONVERSION 90 - 140 - 210
For models 90 - 140 - 210 the complete head set must be replaced, this is available in a conversion kit.
To replace the head set see “Maintenance”.
ATTENTION:
Once the conversion has been carried out it is necessary to put the label, supplied with the conversion kit,
which indicates the figures related to the new adjustments.
This label must replace the one present on the burner (adjustment label).