• Installation in boiler
Place of installation
The room where the boiler and burner are installed must have openings to the outside as required by
current regulations. If there are several burners or exhausters that can work together in the same room,
the ventilation openings must be sized for simultaneonus operation of all the units.
The place of installation must be free of flammable materials or objects, corrosive gases, dusts or vo
-
latile substances which, drawn by the fan, can obstruct yhe pipes inside the burner or the combustion
head. The room must be dry and not exposed to rain, snow or frost.
Fix the burner to the door. Make the electrical connections as described in section (wiring diagram).
Insert the temperature probe (contained in the kit) in the sheating on the cast-iron boiler shell and make
the respective electrical connections.
THE BURNER IS DESIGNED TO WORK ON HEAT GENERATORS WITH COMBUSTION CHAMBER
IN NEGATIVA PRESSURE.
THE PELLET CONTAINER MUST BE POSITIONED SO THAT THE AUGER/BURNER FLEXIBLE
CONNECTION TUBE IS NOT TWISTED AND/OR BENT.
Fixing to the boiler
Fig.4