TECHNICAL FEATURES
PRESSURE CURVES
Combustion chamber pressure
EM 35-E
100
120
140
160
180
200
220
240
260
280
300
320
340
360
380
400
6
4
3
2
1
0
EM 40/M-E
5
EM 40/2-E
1009DIS1373
Thermal output
The pressure curves indicate the output in
kW according to the backpressure in the
combustion chamber, in mbars.
DESCRIPTION
EM 35-E
EM 40/2-E
EM 40/M-E
Thermal output
min.
188
115
kW
max.
320
390
kW
min.
161.680
98.900
kcal/h
max.
275.200
335.400
kcal/h
B/P delivery
min.
7
4,3
m
3
/h
max.
12
14,7
m
3
/h
Methane delivery
min.
19,9
12,2
m
3
/h
max.
33,9
41,3
m
3
/h
Methane pressure
20
20
mbars
B/P pressure
30
30
mbars
Motor
370
370
W
Condenser 450 V
14
14
mF
Transformer
12/35 - 15/40
kV/mA
Total absorbed power
645
1000
W
Flame check
Ionizzazione
Air adjustment
Manual
Motor-driven
Stages
1
2/Modulating
Weight
40
41
kg
Power supply
230V-50/60Hz (*) single-phase
Category
II2H3P
NOTE:
Fuel consumption figures refer to gas with 15°C and 1013 mbar.
(*) 60Hz operation only with electronic transformer.
Summary of Contents for EM 40/2-E
Page 2: ......
Page 25: ...25 ITALIANO...
Page 47: ...47 ENGLISH...
Page 69: ...69 FRAN AIS...
Page 91: ...91 DEUTSCH...
Page 113: ...113 ESPA OL...
Page 115: ...115 a b c d CO2 CO2 CO2...
Page 116: ...116 119 133...
Page 120: ...120 2 n 4 3 4 5 1 A B C D...
Page 121: ...121 2...
Page 126: ...126 3 sec 3 sec LME 10...
Page 127: ...127 B 1 2 3 B H EM 35 E H H EM 40 2 E EM 40 M E H fi 1 max E E 1 E 2 E VE 2 2 14 10 13 SQN 71...
Page 132: ...132 3 A CO2 CO2 CO2 8 5 10 11 12 B P CO CO CO 0 1 160 C 220 C TPR TS B P...
Page 134: ...134 1 A B A B 2 A B C A B C 3 A A...
Page 135: ......