37
BOILER IGNITION
Connect the plug and check that the voltage presence lamp lights up.
- Connect the plug or start the switch upstream of the boiler. The voltage presence lamp lights up.
- Turn the main switch on
- Set the desired temperatures on the adjusting thermostat (and on the priority thermostat). Set the hot water
adjusting thermostat at 80°C.
- After a few seconds the gas will start exiting from the main burner, and the igniter will set the spark. After 10
seconds max., the igniter will stop operating and the main burner will stay on.
- If the boiler does not stay on, contact a qualified technician.
BOILER SHUT OFF
Turn the main switch off
Close the manual gas on-off valve placed outside the boiler or outside the boiler room
WARNING:
if the boiler or parts of the plant can go below 0°C, introduce anti-freeze into the plant.
WARNINGS
Have the boiler inspected every year by a qualified technician to check its efficiency and wear, and to check
that the same is perfectly cleaned.
Check the water heater anode every 6 months. If the same is worn out, replace it so as to prevent rust formation
in the hot water and piercing in the water heater caused by electrochemical corrosion.
BOILER MAINTENANCE - USER INFORMATION
The operations that the user can perform on the boiler are only as follows:
- Check the quantity of water in the boiler and in the plant (at least once a week)
- Unlock the circulators when they have been inactive for over 15 days (turn the main switch off, unscrew the
chromed screw on the circulators (the leakage of some water is normal) and free the rotor with a screwdriver)
- Unlock the safety thermostat and the reset lock-out pushbutton (if boiler is locked-out)
-
Check the anode - SIMPLETEST
-: when the small red knob on the anode is rotated in counter clockwise
direction, no water must leak. If water leaks, the anode has reached an 80% wear. Contact the Technical
Service to replace it
If this check is not performed, the water heater guarantee will not be valid anymore, and the water
heater integrity will be impaired.
- In case of doubts, or if the boiler reset operations must be performed more than three times, contact a
qualified technician.