44
P16
P17
P18
P19
P20
P21
P22
P23
P24
P25
P26
P27
P28
P29
maximum parallel activation time of the hot
water circulator and heating circulator, in hot
water priority operation (if “0” applies, the
function is excluded)
proportional constant (PID) - Vmix
derivative constant – Vmix
proportional band +/- (PID) - Vmix
cycle time (PID) – Vmix
Total shut off (0 = on/1 = off)
priority operation for hot water supply (1 =
inserted/0 = not inserted)
00 hot water priority operation with timer
01 hot water recirculation with timer
burner first stage operation hour counter pre-
setting
burner second stage operation hour counter
setting
no. 1 plant circulator hour counter operation
presetting
no. 2 plant circulator hour counter operation
presetting
no. 3 plant circulator hour counter operation
presetting
no. 4 plant circulator hour counter operation
presetting
ID
Code
Value range
Values set
(default)
Parameter
00
Do not use
Do not use
Do not use
Do not use
00
01
Do not use
First stage hour counter
Do not use
Plant 1 hour counter
Plant 2 hour counter
Plant 3 hour counter
Plant 4 hour counter
from 00 min to 60 min
from 01 to 30
from 01 to 30
from 01°C to 30°C
from 01 sec to 30 sec
from 00 to 01
from 00 to 01
from 00 to 01
from 0000 h to 19999 h
from 0000 h to 19999 h
from 0000 h to 19999 h
from 0000 h to 19999 h
from 0000 h to 19999 h
from 0000 h to 19999 h
Summary of Contents for ERA 31 BS 130
Page 2: ...2...
Page 11: ...11 PROGRAMMAZIONE DEL CRONODATARIO...
Page 28: ...28...
Page 37: ...37 PROGRAMMING THE HOUR DATE COUNTER...
Page 54: ...54...
Page 63: ...63 PROGRAMACI N DEL RELOJ PROGRAMMADOR DIGITAL...
Page 80: ...80...
Page 89: ...89 ACERTARO REL GIO PROGRAMADOR...
Page 106: ...106...
Page 107: ...107...