background image

ERA F 23 - 32 - 45 - 56

43

RO

2. INSTALAREA
2.1 Dispozi

Ġ

ii generale

B

Acest aparat trebuie s

ă

 fie destinat numai utiliz

ă

rii pentru care a fost proiectat

în mod expres. Acest aparat serve

ú

te la înc

ă

lzirea apei la o temperatur

ă

 infe-

rioar

ă

 celei de fierbere la presiune atmosferic

ă

 

ú

i trebuie s

ă

 fie racordat la o in-

stala

Ġ

ie de înc

ă

lzire 

ú

i/sau la o instala

Ġ

ie de distribu

Ġ

ie a apei calde pentru uz

menajer, compatibil

ă

 cu caracteristicile 

ú

i capacit

ăĠ

ile sale 

ú

i cu puterea sa ter-

mic

ă

. Orice alt

ă

 utilizare este considerat

ă

 necorespunz

ă

toare.

INSTALAREA CENTRALEI TREBUIE EFECTUAT

Ă

 NUMAI DE PERSONAL SPECIA-

LIZAT 

ù

I CU CALIFICARE ATESTAT

Ă

, RESPECTÂNDU-SE TOATE INSTRUC

ğ

IUNI-

LE MEN

ğ

IONATE ÎN PREZENTUL MANUAL TEHNIC, DISPOZI

ğ

IILE LEGALE ÎN

VIGOARE 

ù

I EVENTUALELE NORME LOCALE, CONFORM REGULILOR DE BUN

Ă

FUNC

ğ

IONARE TEHNIC

Ă

.

O instalare gre

ú

it

ă

 a centralei poate cauza pagube persoanelor, animalelor 

ú

i bunurilor,

pentru care produc

ă

torul nu poate fi tras la r

ă

spundere.

2.2 Locul de instalare

Centrala trebuie instalat

ă

 într-o înc

ă

pere adecvat

ă

, cu deschideri de aerisire spre exte-

rior, conform prevederilor normelor în vigoare. Dac

ă

 în aceea

ú

i înc

ă

pere se afl

ă

 mai mul-

te arz

ă

toare sau aspiratoare care pot func

Ġ

iona împreun

ă

, deschiderile de aerisire

trebuie s

ă

 fie dimensionate pentru func

Ġ

ionarea simultan

ă

 a tuturor aparatelor. În locul

de instalare nu trebuie s

ă

 se afle obiecte sau materiale inflamabile, gaze corozive, pul-

beri sau substan

Ġ

e volatile care, absorbite de ventilatorul arz

ă

torului, pot bloca tuburile

interne ale arz

ă

torului sau capul de ardere. Înc

ă

perea trebuie s

ă

 fie uscat

ă

 

ú

i s

ă

 nu fie

expus

ă

 ploii, z

ă

pezii sau înghe

Ġ

ului.

A

Dac

ă

 aparatul este inclus într-un corp de mobilier sau montat lâng

ă

 piese de

mobilier, trebuie asigurat spa

Ġ

iul pentru demontarea carcasei 

ú

i pentru de-

sf

ăú

urarea activit

ăĠ

ilor normale de între

Ġ

inere.

2.3 Racordurile hidraulice

Puterea termic

ă

 a aparatului trebuie stabilit

ă

 în prealabil cu un calcul al necesarului de

c

ă

ldur

ă

 al cl

ă

dirii, conform normelor în vigoare. Pentru buna func

Ġ

ionare 

ú

i pentru o lung

ă

durat

ă

 de via

Ġă

 a centralei, instala

Ġ

ia hidraulic

ă

 trebuie s

ă

 fie bine propor

Ġ

ionat

ă

 

ú

i în-

totdeauna complet

ă

, cu toate acele accesorii care garanteaz

ă

 o func

Ġ

ionare 

ú

i o ac

Ġ

iona-

re normale. 
În cazul în care 

Ġ

evile de tur 

ú

i de retur ale instala

Ġ

iei urmeaz

ă

 un parcurs datorit

ă

 c

ă

ruia,

în anumite puncte, se pot forma pungi de aer, este necesar

ă

 instalarea, în aceste pun-

cte, a unei valve de aerisire. Instala

Ġ

i, de asemenea, un dispozitiv de evacuare în punctul

cel mai de jos al instala

Ġ

iei, pentru a permite golirea sa complet

ă

.

Dac

ă

 centrala este instalat

ă

 la un nivel inferior fa

Ġă

 de nivelul instala

Ġ

iei, este necesar

ă

montarea unei supape de întrerupere a debitului (flow-stop) pentru a împiedica circula

Ġ

ia

natural

ă

 a apei în instala

Ġ

ie.

Se recomand

ă

 ca diferen

Ġ

a de temperatur

ă

 între colectorul de tur 

ú

i cel de retur în cen-

tral

ă

 s

ă

 nu dep

ăú

easc

ă

 20°C.

B

Nu utiliza

Ġ

Ġ

evile instala

Ġ

iilor hidraulice ca împ

ă

mântare pentru aparatele

electrice.

Înainte de instalare, efectua

Ġ

i o sp

ă

lare corect

ă

 a tuturor 

Ġ

evilor instala

Ġ

iei, pentru a înde-

p

ă

rta reziduurile sau impurit

ăĠ

ile care ar putea compromite buna func

Ġ

ionare a apara-

tului.
Efectua

Ġ

i racordurile în punctele corespunz

ă

toare, a

ú

a cum se indic

ă

 în fig. 22.

Se recomand

ă

 s

ă

 interpune

Ġ

i, între central

ă

 

ú

i instala

Ġ

ia de înc

ă

lzire, supape de blocare

care s

ă

 permit

ă

, dac

ă

 este necesar, izolarea centralei de instala

Ġ

ie.

B

Racorda

Ġ

i centrala astfel încât tuburile interne s

ă

 nu aib

ă

 tensiuni.

Caracteristicile apei din instala

Ġ

ie

Dac

ă

 apa are o duritate mai mare de 25° Fr (1°F = 10 ppm CaCO

3

), se recomand

ă

 s

ă

se utilizeze ap

ă

 tratat

ă

 corespunz

ă

tor, pentru a evita posibilele incrusta

Ġ

ii în central

ă

.

Tratarea nu trebuie s

ă

 reduc

ă

 duritatea la valori mai mici de 15°F (DPR 236/88 pentru

utilizarea apei destinate consumului uman). Este indispensabil s

ă

 se trateze apa utilizat

ă

în cazul instala

Ġ

iilor foarte mari sau în cazul în care în instala

Ġ

ie se introduce frecvent ap

ă

pentru completare. Dac

ă

, în aceste cazuri, se dovede

ú

te necesar

ă

 ulterior golirea

par

Ġ

ial

ă

 sau total

ă

 a instala

Ġ

iei, se recomand

ă

 s

ă

 se efectueze din nou umplerea cu ap

ă

tratat

ă

.

Conectarea la un boiler pentru ap

ă

 cald

ă

 menajer

ă

Cartela electronic

ă

 a aparatului e prev

ă

zut

ă

 pentru ac

Ġ

ionarea unui boiler extern pentru

prepararea apei calde menajere. Efectua

Ġ

i racordurile hidraulice conform schemei fig. 16

(pompele 

ú

i supapele unisens trebuie furnizate separat). Efectua

Ġ

i  conexiunile electrice

a

ú

a cum se arat

ă

 în schema electric

ă

 din cap. 4. Trebuie s

ă

 se utilizeze o sond

ă

 LAM-

BORGHINI. Sistemul de control al centralei, la urm

ă

toarea aprindere, recunoa

ú

te pre-

zen

Ġ

a sondei boilerului 

ú

i se configureaz

ă

 automat, activând afi

ú

ajul 

ú

i comenzile relative

la func

Ġ

ia de prepararea a apei calde menajere.

fig. 16 - Schema de conectare la un boiler extern

Legend

ă

8

Ie

ú

ire ap

ă

 menajer

ă

9

Intrare ap

ă

 rece menajer

ă

10

Tur instala

Ġ

ie

11

Retur instala

Ġ

ie

2.4 Racordarea la gaz

B

Înainte de efectuarea racord

ă

rii, verifica

Ġ

i ca aparatul s

ă

 fie proiectat pentru

func

Ġ

ionarea cu tipul de combustibil disponibil 

ú

i efectua

Ġ

i o cur

ăĠ

are corect

ă

 a

tuturor 

Ġ

evilor de gaz ale instala

Ġ

iei, pentru a îndep

ă

rta eventualele reziduuri

care ar putea compromite buna func

Ġ

ionare a centralei.

Racordul la gaz trebuie s

ă

 fie efectuat în punctul corespunz

ă

tor (vezi fig. 22) în confor-

mitate cu normele în vigoare, cu o 

Ġ

eav

ă

 metalic

ă

 rigid

ă

, sau la perete cu o 

Ġ

eav

ă

 flexibil

ă

continu

ă

 din o

Ġ

el inox, interpunând un robinet de gaz între instala

Ġ

ie 

ú

i central

ă

. Verifica

Ġ

i

ca toate racord

ă

rile la gaz s

ă

 fie etan

ú

e.

Debitul gazometrului trebuie s

ă

 fie suficient pentru utilizarea simultan

ă

 a tuturor apara-

telor racordate la acesta. Diametrul conductei de gaz care iese din central

ă

 nu este de-

terminant pentru alegerea diametrului conductei între aparat 

ú

i gazometru; aceasta

trebuie s

ă

 fie aleas

ă

 în func

Ġ

ie de lungimea sa 

ú

i de pierderile de sarcin

ă

, în conformitate

cu normele în vigoare.

2.5 Racordurile electrice
Racordarea la re

Ġ

eaua electric

ă

Centrala trebuie racordat

ă

 la o re

Ġ

ea electric

ă

 monofazat

ă

, 230 Volt-50 Hz.

B

Siguran

Ġ

a electric

ă

 a aparatului este ob

Ġ

inut

ă

 numai când acesta este racordat

corect la o instala

Ġ

ie eficient

ă

 de împ

ă

mântare, realizat

ă

 în conformitate cu nor-

mele de siguran

Ġă

 în vigoare. Solicita

Ġ

i personalului calificat profesional s

ă

 ve-

rifice eficien

Ġ

ú

i compatibilitatea instala

Ġ

iei de împ

ă

mântare, produc

ă

torul

nefiind responsabil pentru eventualele pagube cauzate de neefectuarea îm-
p

ă

mânt

ă

rii instala

Ġ

iei. Solicita

Ġ

i de asemenea s

ă

 se verifice dac

ă

 instala

Ġ

ia

electric

ă

 este adecvat

ă

 pentru puterea maxim

ă

 absorbit

ă

 a aparatului, indicat

ă

pe pl

ă

cu

Ġ

a cu datele tehnice ale centralei, controlând în special ca sec

Ġ

iunea

cablurilor instala

Ġ

iei s

ă

 fie adecvat

ă

 pentru puterea absorbit

ă

 a aparatului.

Centrala este precablat

ă

 

ú

i e dotat

ă

 cu o serie de conectoare pentru racord

ă

ri la posibile

componente accesorii, ca de ex. pompe de circula

Ġ

ie, valve de amestecare, precum 

ú

i la

o unitate electronic

ă

 termostatic

ă

 (vezi schemele electrice). De asemenea, centrala este

dotat

ă

 cu un conector pentru racordarea la re

Ġ

eaua electric

ă

. Conexiunile la re

Ġ

ea trebuie

efectuate cu un racord fix 

ú

i trebuie s

ă

 fie dotate cu un întrerup

ă

tor bipolar ale c

ă

rui con-

tacte s

ă

 aib

ă

 o deschidere de cel pu

Ġ

in 3 mm, interpunând siguran

Ġ

e de max. 3A între

central

ă

 

ú

i linie. Este important s

ă

 respecta

Ġ

i polarit

ăĠ

ile (LINIE: cablu maro / NUL: cablu

albastru / ÎMP

Ă

MÂNTARE: cablu galben-verde) la conexiunile la linia electric

ă

.

Termostatul de camer

ă

B

Termostatul de camer

ă

 trebuie s

ă

 aib

ă

 contactele curate. Dac

ă

 se co-

necteaz

ă

 230 V. la bornele termostatului de camer

ă

, se deterioreaz

ă

 ire-

mediabil unitatea electronic

ă

 de control al fl

ă

c

ă

rii.

La racordarea unui eventual termostat de camer

ă

 cu program zilnic sau s

ă

p-

t

ă

mânal, sau a unui întrerup

ă

tor orar (temporizator), evita

Ġ

i s

ă

 decupla

Ġ

i alimen-

tarea acestor dispozitive de la contactele lor de întrerupere. Alimentarea lor
trebuie efectuat

ă

 prin intermediul unei conexiuni directe la re

Ġ

ea sau prin baterii,

în func

Ġ

ie de tipul de dispozitiv.

2.6 Conducte aer/gaze arse

Tubul de racordare la horn trebuie s

ă

 aib

ă

 un diametru care s

ă

 nu fie mai mic decât dia-

metrul racordului la dispozitivul de antirefulare. Începând de la dispozitivul de antirefulare
trebuie s

ă

 aib

ă

 o por

Ġ

iune vertical

ă

 cu o lungime de minim jum

ă

tate de metru. În ceea ce

prive

ú

te dimensionarea 

ú

i montarea hornurilor 

ú

i a tubului de racordare la acestea, este

obligatoriu s

ă

 respecta

Ġ

i normele în vigoare.

Centrala este de tip 

B11BS

 

ú

i este dotat

ă

 cu un dispozitiv de siguran

Ġă

 (termostat de

gaze arse) care întrerupe alimentarea cu gaz 

ú

i blocheaz

ă

 func

Ġ

ionarea aparatului în caz

de tiraj neadecvat sau de perturbare a evacu

ă

rii produselor de ardere. Blocarea apara-

tului este indicat

ă

 pe afi

ú

aj cu codul 

F04

 (det. cap. 3.4). Aparatul porne

ú

te din nou, au-

tomat, dup

ă

 ce au trecut 20 de minute de la terminarea anomaliei care a cauzat

problema. În cazul unor declan

úă

ri repetate ale dispozitivului, contacta

Ġ

i personalul cali-

ficat pentru a verifica hornul 

ú

i co

ú

ul 

ú

i pentru a remedia defec

Ġ

iunile legate de evacuarea

gazelor arse.

B

Acest dispozitiv de siguran

Ġă

 nu trebuie s

ă

 fie modificat sau dezactivat nicioda-

t

ă

. Orice interven

Ġ

ia asupra dispozitivului sau înlocuirea sa trebuie s

ă

 fie efec-

tuate numai de personal calificat, folosind doar piese de schimb originale de la
produc

ă

tor. Este necesar s

ă

 se efectueze o prob

ă

 de func

Ġ

ionare dup

ă

 fiecare

interven

Ġ

ie asupra dispozitivului.

8
9

10

11

cod. 3540L893  -  Rev. 01 - 03/2018

Summary of Contents for ERA F23

Page 1: ...FOR USE INSTALLATION AND MAINTENANCE FR INSTRUCTIONS D UTILISATION D INSTALLATION ET D ENTRETIEN ES INSTRUCCIONES DE USO INSTALACI N Y MANTENIMIENTO RO INSTRUC IUNI DE UTILIZARE INSTALARE I NTRETINER...

Page 2: ...ly using the switch and or the special cut off devices In case of a fault and or poor operation deactivate the unit and do not try to repair it or directly intervene Contact pro fessionally qualified...

Page 3: ...ion 7 2 3 Plumbing connections 7 2 4 Gas connection 7 2 5 Electrical connections 7 2 6 Air fume ducts 7 3 Service and maintenance 8 3 1 Adjustments 8 3 2 Start up 9 3 3 Maintenance 9 3 4 Troubleshooti...

Page 4: ...rt mode selection button 8 Winter mode 9 DHW operation 10 Summer mode 11 Multifunction 12 C Comfort mode 13 Heating mode 14 Shutdown type fault 15 Burner On 16 All the arrows light up together on conn...

Page 5: ...10 fig 1 the boiler will only deliver domestic hot water The antifreeze system remains activated To deactivate Summer mode press the button R detail 6 fig 1 again for 1 second Heating temperature adju...

Page 6: ...fig 14 Example of compensation parallel curve offset A If the Remote Timer Control optional is connected to the boiler the above ad justments are managed according to that given in table 1 Table 1 Wat...

Page 7: ...utomatically configures the DHW function activating the display and relevant controls fig 16 Diagram of connection to external hot water tank Key 8 Domestic hot water outlet 9 Domestic cold water inle...

Page 8: ...t changed Refit the protection cap D To end TEST mode repeat the activation sequence or wait 15 minutes A After checking or adjusting the pressure make sure to seal the adjust ment screw with paint or...

Page 9: ...ty devices B If the burners do not light and the block indicator comes on after correctly car rying out the lighting procedures wait approx 15 seconds then press the button R detail 6 fig 1 The reset...

Page 10: ...d in the top part of the anti backflow device see fig 20 detail 3 To take samples 1 Remove the upper panel of the boiler 2 Remove the insulation above the anti backflow device 3 Open the fume sampling...

Page 11: ...system Vent the system F04 Fume thermostat activation after activation of the fume thermostat boiler operation is inhibited for 20 minutes Fume thermostat contact open Check the thermostat Wiring disc...

Page 12: ...Min pressure at burner G20 mbar 2 5 2 5 2 5 2 5 Max gas delivery G20 m3 h 2 68 3 69 5 24 6 52 Min gas delivery G20 m3 h 1 07 1 58 2 08 2 59 Burner nozzles G31 no x 2 x 1 75 3 x 1 75 4 x 1 75 5 x 1 75...

Page 13: ...ostat 81 Ignition electrode 82 Detection electrode 114 Water pressure switch optional 126 Fume thermostat 130 Hot water tank circulating pump optional 138 External probe 139 Remote timer control OpenT...

Page 14: ...dispositifs d isolement pr vus D sactiver l appareil en cas de panne et ou de mauvais fonctionnement en s abstenant de toute tentative de r pa ration ou d intervention directe S adresser uniquement un...

Page 15: ...ts hydrauliques 19 2 4 Raccordement gaz 19 2 5 Branchements lectriques 19 2 6 Conduits d air de fum e 19 3 Utilisation et entretien 20 3 1 R glages 20 3 2 Mise en service 21 3 3 Entretien 21 3 4 D pan...

Page 16: ...e Extinction appareil 8 Indication mode hiver 9 Indication du fonctionnement eau chaude sanitaire 10 Indication fonction t 11 Indication multifonction 12 Indication mode C Confort 13 Indication foncti...

Page 17: ...ne fournira que de l eau chaude sanitaire Le syst me antigel reste actif Pour d sactiver le mode t appuyer nouveau sur la touche R rep 6 fig 1 pendant 1 seconde R glage de la temp rature de chauffage...

Page 18: ...stance option les r gla ges ci dessus seront g r s comme indiqu dans le tableau tableau 1 Tableau 1 R glage de la pression hydraulique de l installation La pression de remplissage installation froid l...

Page 19: ...is s par ment Effectuer les raccordements lectriques comme l indique le sch ma lectrique au cap 4 Utiliser une sondeLAMBORGHINI Le syst me de contr le de la chaudi re l allumage suivant reconna t la p...

Page 20: ...d une montre pour la diminuer et dans le sens inverse pour l augmenter Rebrancher le faston s par du modureg sur la vanne gaz V rifier que la pression maximale n ait subi aucune variation Remettre en...

Page 21: ...lution des probl mes A Au cas o l alimentation lectrique vers la chaudi re vendrait manquer alors que celle ci est en fonctionnement les br leurs s teindront et se rallumeront automatiquement d s le r...

Page 22: ...ter l isolation recouvrant l antirefouleur 3 Ouvrir le point de pr l vement des fum es 4 Introduire la sonde 5 R gler la temp rature de la chaudi re sur la valeur maximum 6 Attendre 10 15 minutes pou...

Page 23: ...clenchement du thermostat s curit fum es apr s son d clenchement le fonctionne ment de la chaudi re est d sactiv pendant 20 minutes Contact de thermostat s curit fum es ouvert V rifier le thermostat C...

Page 24: ...15 0 Pression mini au br leur G20 mbar 2 5 2 5 2 5 2 5 D bit gaz puissance maxi G20 m3 h 2 68 3 69 5 24 6 52 D bit gaz puissance mini G20 m3 h 1 07 1 58 2 08 2 59 Gicleurs br leur G31 nbre x 2 x 1 75...

Page 25: ...Thermostat d ambiance 81 lectrode d allumage 82 lectrode de d tection 114 Pressostat eau en option 126 Thermostat fum es 130 Circulateur ballon option 138 Sonde ext rieure 139 Chronocommande distance...

Page 26: ...n u otro dispositivo de corte En caso de aver a o funcionamiento incorrecto del equipo desconectarlo y hacerlo reparar nicamente por un t cnico autorizado Acudir exclusivamente a personal autorizado...

Page 27: ...exiones hidr ulicas 31 2 4 Conexi n del gas 31 2 5 Conexiones el ctricas 31 2 6 Conductos de aire y humos 31 3 Servicio y mantenimiento 32 3 1 Regulaciones 32 3 2 Puesta en servicio 33 3 3 Mantenimien...

Page 28: ...do del aparato 8 Indicaci n de modalidad Invierno 9 Indicaci n de funcionamiento en producci n de ACS 10 Indicaci n de modalidad Verano 11 Indicaci n multifunci n 12 Indicaci n de modalidad C Confort...

Page 29: ...inistra agua sanitaria El sistema antihielo permanece operativo Para desactivar la modalidad Verano pulsar nuevamente la tecla R 6 fig 1 durante un segundo Regulaci n de la temperatura de calefacci n...

Page 30: ...rmente se gestionan seg n lo indicado en la tabla 1 Tabla 1 Regulaci n de la presi n hidr ulica de la instalaci n La presi n de carga con la instalaci n fr a le da en el hidr metro de la caldera tiene...

Page 31: ...encender la caldera el sis tema de control reconoce la sonda del acumulador y se configura autom ticamente ac tivando la pantalla y los controles de la funci n para agua sanitaria fig 16 Esquema para...

Page 32: ...Para salir del modo TEST repetir la secuencia de activaci n o dejar pasar quince minutos A Tras controlar la presi n o regularla es obligatorio sellar el tornillo de re gulaci n con pintura o con un...

Page 33: ...iclo de encendido Si despu s del segundo intento los quemadores siguen sin encenderse consultar el p rrafo Soluci n de proble mas A Si se interrumpe el suministro el ctrico mientras la caldera est en...

Page 34: ...aldera 2 Quitar el aislante que cubre el cortatiro 3 Abrir el punto de toma de humos 4 Introducir la sonda 5 Regular la temperatura de la caldera al m ximo 6 Esperar a que transcurran unos diez o quin...

Page 35: ...del termostato de humos tras la interven ci n del termostato de humos el funcionamiento de la caldera se inhabilita durante 20 minutos Contacto del termostato de humos abierto Controlar el termostato...

Page 36: ...20 mbar 15 13 15 15 Presi n m nima quemador con G20 mbar 2 5 2 5 2 5 2 5 Caudal m ximo G20 m3 h 2 68 3 69 5 24 6 52 Caudal m nimo G20 m3 h 1 07 1 58 2 08 2 59 Inyectores quemador G31 n x 2 x 1 75 3 x...

Page 37: ...72 Termostato de ambiente 81 Electrodo de encendido 82 Electrodo de detecci n 114 Presostato del agua opcional 126 Termostato de los humos 130 Bomba de circulaci n del acumulador opcional 138 Sonda e...

Page 38: ...ntrerup torului instala iei i sau cu ajutorul dispozitivelor corespunz toare de blocare n caz de defec iune i sau de func ionare defectuoas a aparatului dezactiva i l evit nd orice ncercare de repara...

Page 39: ...rdurile hidraulice 43 2 4 Racordarea la gaz 43 2 5 Racordurile electrice 43 2 6 Conducte aer gaze arse 43 3 Exploatarea i ntre inerea 44 3 1 Regl rile 44 3 2 Punerea n func iune 45 3 3 ntre inerea 45...

Page 40: ...t selectare mod Economy Comfort Aprindere Stingere aparat 8 Indicator mod Iarn 9 Indicator func ionare ap cald menajer 10 Indicator mod Var 11 Indicator multifunc ional 12 Indicator modul C Comfort 13...

Page 41: ...ai ap cal d menajer R m ne activ sistemul anti nghe Pentru a dezactiva modul Var ap sa i din nou pe tasta R det 6 fig 1 timp de 1 se cund Reglarea temperaturii n circuitul de nc lzire Cu ajutorul buto...

Page 42: ...central este conectat Croncomanda la distan op ional regl rile de mai sus trebuie efectuate conform indica iilor din tabel 1 Tabel 1 Reglarea presiunii hidraulice din instala ie Presiunea de umplere...

Page 43: ...se configureaz automat activ nd afi ajul i comenzile relative la func ia de prepararea a apei calde menajere fig 16 Schema de conectare la un boiler extern Legend 8 Ie ire ap menajer 9 Intrare ap rece...

Page 44: ...a de gaz Verifica i ca presiunea maxim s nu fie schimbat Pune i la loc capacul de protec ie D Pentru a ie i din modul TEST repeta i secven a de activare sau a tepta i 15 minute A Dup ce s a efectuat c...

Page 45: ...dere arz toarele nu se aprind iar indicatorul de blocare se lumineaz a tepta i aproximativ 15 secun de i apoi ap sa i butonul R det 6 fig 1 Unitatea reini ializat va repeta ci clul de aprindere Dac ni...

Page 46: ...un punct pentru prelevarea gazelor arse vezi fig 20 det 3 Pentru a efectua prelevarea proceda i astfel 1 Scoate i panoul superior al centralei 2 Scoate i izolatorul aflat deasupra dispozitivul antire...

Page 47: ...ala ie F04 Interven ia termostatului pentru gaze arse dup interven ia termostatului gaze arse func ionarea centralei e blocat timp de 20 minute Contact termostat gaze arse deschis Verifica i termostat...

Page 48: ...0 13 0 15 0 15 0 Presiune min la arz tor G20 mbar 2 5 2 5 2 5 2 5 Debit gaz max G20 m3 h 2 68 3 69 5 24 6 52 Debit gaz min G20 m3 h 1 07 1 58 2 08 2 59 Duze arz tor G31 nr x 2 x 1 75 3 x 1 75 4 x 1 7...

Page 49: ...72 Termostatul de camer 81 Electrod de aprindere 82 Electrod de detectare 114 Presostat ap op ional 126 Termostat gaze arse 130 Pomp de circula ie boiler op ional 138 Sond extern 139 Cronocomand la di...

Page 50: ...50 ERA F 23 32 45 56 RU B B A Lamborghini Calor S p A 24 24 10 cod 3540L893 Rev 01 03 2018...

Page 51: ...ERA F 23 32 45 56 51 RU 1 52 1 1 52 1 2 52 1 3 52 1 4 53 2 55 2 1 55 2 2 55 2 3 55 2 4 55 2 5 55 2 6 55 3 56 3 1 56 3 2 57 3 3 57 3 4 59 4 59 4 1 59 4 2 60 4 3 60 4 4 61 cod 3540L893 Rev 01 03 2018...

Page 52: ...LAM BORGHINI ERA F 23 32 45 56 A sez 2 3 1 2 1 1 2 3 4 5 6 7 Economy Comfort 8 9 10 11 12 C 13 14 15 16 13 1 2 9 1 3 conomy ComforT 12 1 N 7 1 1 2 1 ECO CON N 7 1 1 3 4 B sez 2 3 9 13 11 15 16 2 5 1...

Page 53: ...10 1 R 6 1 1 3 4 1 30 C 85 C 45 C 9 10 C 65 C 1 2 1 10 I I I I I I I I IIII I I I I I I I I I I IIII I I I I I I I I I I IIII I I I I I I I I I I IIII I I I I IIII I I I I I I I I I I I I IIII I I I I...

Page 54: ...I I I I I I I I I I I IIII I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I IIII I I I I I I I I I I IIII I I I I I I I I I I IIII I I ECO COMFORT Economy N 7 1 COMFORT N 7 1 20 3...

Page 55: ...45 56 55 RU 2 2 1 B 2 2 A 2 3 20 C B 22 B 25 Fr 1 F 10 CaCO3 15 F 236 88 16 cap 4 LAMBORGHINI 16 8 9 10 11 2 4 B 22 2 5 230 50 B 3 3 A B 230 2 6 0 5 B11BS F04 cap 3 4 20 B 8 9 10 11 cod 3540L893 Rev...

Page 56: ...ervice 10 2 P01 1 10 Service Reset 10 tS In Hi rE tS In Hi History rE Reset History Reset tS 24 Service I I I I I I I I IIII I I I I I I I I I I IIII I I I I I I I I I I IIII I I I I I I I I I I IIII...

Page 57: ...R 6 1 A sez 1 3 sez 4 3 3 3 B 1 A 12 P12 31 85 C 85 C 13 P13 0 255 30 14 P14 0 255 120 15 P15 0 100 100 16 P16 55 65 C 17 P17 0 20 C 18 P18 70 85 C 19 P19 Non modificabile 0 20 P20 Non modificabile 4...

Page 58: ...ERA F 23 32 45 56 58 RU 19 B 19 1 2 3 4 20 3 1 2 3 4 5 6 10 15 7 A 20 1 2 3 A C D 21 21 1 2 3 1 2 3 4 1 2 3 4 0 5 1 2 3 A C D D cod 3540L893 Rev 01 03 2018...

Page 59: ...A03 F04 20 A06 F10 1 F11 F14 2 F34 170 F35 F37 F39 A41 F42 F50 odureg A B C D E F G A1 A2 A3 ERA F 23 450 137 134 65 480 130 70 1 1 2 1 1 2 1 2 ERA F 32 450 94 91 22 530 150 80 ERA F 45 600 126 123 8...

Page 60: ...0 15 0 13 0 15 0 15 0 G20 2 5 2 5 2 5 2 5 G20 3 2 68 3 69 5 24 6 52 G20 3 1 07 1 58 2 08 2 59 G31 x 2 x 1 75 3 x 1 75 4 x 1 75 5 x 1 75 G31 37 0 37 0 37 0 37 0 G31 35 0 31 0 35 0 35 0 G31 6 0 6 0 6 0...

Page 61: ...38 139 OpenTherm 278 7 6 5 4 3 2 1 11 10 9 8 7 6 5 4 3 2 1 T1 T2 X7 7 6 5 4 3 2 1 6 5 4 3 2 1 X5 F1 F2 X1 X2 X4 X3 X6 X8 X10 2 1 T T 278 L N 230V 50Hz 138 L N 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 12...

Page 62: ...ECTIVES IN FORCE THE DECLARATION OF CONFORMITY MAY BE REQUESTED FROM THE MANUFACTURER 58 FR LE MARQUAGE ATTESTE QUE LES PRODUITS SONT CONFORMES AUX EXIGENCES ESSENTIELLES DE L ENSEMBLE DES DIRECTIVES...

Page 63: ......

Page 64: ...55 300 117393 7 495 785 55 00 7 499 500 00 01 0DGH LQ WDO DEULTXp HQ WDOLH Fabricado en Italia Fabricat n Italia VIA n 047 6...

Reviews: