46
GB
The burner room must always be kept clean and free from volatile substances, which could be sucked inside the
fan and block the interior pipes of the burner and the combustion head. Dust is extremely dangerous, especially if
this can deposit on the fan blades, where it will reduce ventilation and produce pollution during combustion. The
dust an also accumulate on the rear part of the flame stability disc in the combustion head and cause a poor air/
fuel mixture.
The burner must be fed with the type of fuel for which it has been set-up as indicated on the data plate and in
the technical features supplied in this manual. Moreover, it must be supplied with all control and safety devices
requested by local regulations in force. Pay great care that no external material enters the line during installation.
Make sure that the electric power supply used for the connection is in compliance with the features indicated on the
data plate and in this manual.Make an electric plant with an effective connection to an earth plant, in compliance
with Standards in force. The earth cable must be a couple of cm. longer that the phase and neutral wire.
If in doubt regarding efficiency, it must be checked and controlled by qualified staff.Never exchange the neutral
and phase cables.The burner can be connected to the mains electricity with a plug-socket connection only if this is
equipped in a way that the coupling configuration prevents the inversion of phase and neutral.Install an omnipolar
switch with opening between contacts of at least 3mm upstream from the appliance as requested by the existing
legislation.
The entire electric system and in particular all cable sections, must be suitable for the maximum absorbed power
value indicated on the appliance data plate and in this manual.
If the burner power supply cable is faulty, it must only be replaced by qualified staff.Never touch the burner with
wet body parts or without wearing shoes.
Never stretch (force) power supply cables and keep them away from heat sources.The length of the cables used
must allow the burner and any boiler door to be opened.
The electric connections must be made exclusively by qualified staff and the regulations in force on the subject of
electricity must be respected.After all packaging material has been removed, control the contents and ensure that
these have not been damaged in any way during transport.
If in doubt, do not use the burner and contact the supplier.
The packaging materials (wooden cages, cardboard, plastic bags, expanded materials, staples, etc...) represent
a form of pollution and potential risk if left everywhere. Collect them and dispose of them in a suitable manner (in
a suitable place).
The entire electric system and in particular all cable sections, must be suitable for the maximum absorbed power
value indicated on the appliance data plate and in this manual.
If the burner power supply cable is faulty, it must only be replaced by qualified staff.Never touch the burner with
wet body parts or without wearing shoes.
Never stretch (force) power supply cables and keep them away from heat sources.The length of the cables used
must allow the burner and any boiler door to be opened.
The electric connections must be made exclusively by qualified staff and the regulations in force on the subject of
electricity must be respected.
After all packaging material has been removed, control the contents and ensure that these have not been damaged
in any way during transport.
If in doubt, do not use the burner and contact the supplier.
The packaging materials (wooden cages, cardboard, plastic bags, expanded materials, staples, etc...) represent
a form of pollution and potential risk if left everywhere. Collect them and dispose of them in a suitable manner (in
a suitable place).
Summary of Contents for LMB LO 300 2ST
Page 2: ...K d d D Z E Z E Y d s ZZK s Z s...
Page 43: ...43 IT...