Taura 24 MCS W TOP

30

After establishing the parameter to be set, use the following conversion tables to understand the value being set, ac-
cording to the blinking of the LEDs. OFF means LED off, ON means LED on, whereas ON BL means LED blinking.

Red

Green

Yellow

Max. heating power

OFF

OFF

OFF

00-11%

ON BL

OFF

OFF

11-23%

OFF

OFF

ON BL

23-36%

ON BL

OFF

ON BL

36-49%

OFF

ON BL

OFF

49-61%

ON BL

ON BL

OFF

61-74%

OFF

ON BL

ON BL

74-85%

ON BL

ON BL

ON BL

85-100%

Red

Green

Yellow

Gas type selection

OFF

OFF

OFF

Natural gas

ON BL

OFF

OFF

LPG

Red

Green

Yellow

Lighting power

OFF

OFF

OFF

00-06%

ON BL

OFF

OFF

06-13%

OFF

OFF

ON BL

13-21%

ON BL

OFF

ON BL

21-29%

OFF

ON BL

OFF

29-36%

ON BL

ON BL

OFF

36-44%

OFF

ON BL

ON BL

44-51%

ON BL

ON BL

ON BL

51-60%

Red

Green

Yellow

Heating idle time

OFF

OFF

OFF

00 minutes

ON BL

OFF

OFF

2.5 minutes

Red

Green

Yellow

Pump post-circulation

OFF

OFF

OFF

00 minutes

ON BL

OFF

OFF

2.5 minutes

Red

Green

Yellow

Heating max. setpoint

OFF

OFF

OFF

30°C

ON BL

OFF

OFF

40°C

OFF

OFF

ON BL

85°C

Red

Green

Yellow

Hot water max. setpoint 

OFF

OFF

OFF

55°C

ON BL

OFF

OFF

65°C

Red

Green

Yellow

Hot water burner shutdown

OFF

OFF

OFF

Fixed shutdown

ON BL

OFF

OFF

Tied to user setpoint

Summary of Contents for Taura 24 MCS W TOP

Page 1: ...DE GAS CON C MARA ESTANCA PARA AGUA SANITARIA Y CALEFACCI N CALDEIRA MURAL A G S C MARA ESTANQUE PARA PRODU O DE GUA QUENTE SANIT RIA E AQUECIMENTO cod 3540D95 0 ediz 06 2006 AZIENDA CERTIFICATA ISO 9...

Page 2: ...nit breaks down and or functions poorly deactivate it do not make any attempt to repair it or directly intervene Contact profession ally qualified personnel Any repair replacement of products must onl...

Page 3: ...iency heat generator for heating and hot water production running on natural or liquefied petroleum gas equipped with an open flue burner with electronic ignition airtight chamber with forced ventilat...

Page 4: ...s Water system pressure adjustment The filling pressure with the system cold read on the boiler water gauge must be about 1 0 1 5 bar If the system pressure falls to values below the minimum bring it...

Page 5: ...y under these conditions it is advisable to refill it with treated water Antifreeze system antifreeze fluids additives and inhibitors The boiler is equipped with an antifreeze system that turns on the...

Page 6: ...city line The connections to the grid must be made with a permanent connection and equipped with a bipolar switch whose contacts have a minimum opening of at least 3 mm interposing fuses of max 3A bet...

Page 7: ...for coaxial pipes Insert the diaphragm on the aluminium section 60 of the upper flange of the boiler Diaphragm for separate pipes Insert the diaphragm under the flanged air inlet section 80 84 Connec...

Page 8: ...tion protection air end piece 80 2 Rooftop outlet 80 125 TEE reduction for separate ducts 12 Caution use solely Lamborghini Caloreclima fume suction outlet kits Air suction 80 Air diaphragm Air Fumes...

Page 9: ...ct WINTER yellow LED on select RESET for 5 seconds LEDs blinking fast for two seconds select WINTER turn the hot water knob ref 2 fig 1 onto minimum for Natural Gas operation or onto maximum for LPG o...

Page 10: ...00 100 2 Gas type selection 0 Natural gas 1 LPG 0 Natural gas 3 Lighting Power 0 60 50 4 Heating idle time 0 0minutes 1 2 5 minutes 1 2 5 minutes 5 Heating pump Post Circulation 0 0minutes 1 2 5 minut...

Page 11: ...onds turn to Winter when the 3 LEDs blink fast Selector turned to Reset for 5 seconds turn to Winter when the 3 LEDs blink fast Selector turned to Reset for 5 seconds turn to Winter when the 3 LEDs bl...

Page 12: ...OFF OFF Natural gas ON BL OFF OFF LPG Red Green Yellow Lighting power OFF OFF OFF 00 06 ON BL OFF OFF 06 13 OFF OFF ON BL 13 21 ON BL OFF ON BL 21 29 OFF ON BL OFF 29 36 ON BL ON BL OFF 36 44 OFF ON B...

Page 13: ...ated on the meter corresponds to that given in the technical data table in chap 4 Make sure that with no call for heating the burner correctly ignites on opening a hot water tap Check that during heat...

Page 14: ...hot water temperature to maximum 4 Wait 10 15 minutes for the boiler to stabilize 5 Take the measurement Analyses made with an unstabilized boiler can cause measurement errors Air Fumes Fig 5 Opening...

Page 15: ...Tap water sensor fault Fault Possible cause Cure Green Yellow Red Heating sensor damaged No circulation of water in the system Air in the system Check the gas flow to the boiler is regular Check the w...

Page 16: ...ig 6 Top view Bottom view Key 1 Heating system delivery 3 4 2 Hot water outlet 1 2 3 Gas inlet 1 2 4 Tap water inlet 1 2 5 Heating system return 3 4 If using the LEJ LINE plumbing kit the distances fo...

Page 17: ...amber 20 Burner assembly 21 Main nozzle 22 Burner 26 Combustion chamber insulation 27 Copper exchanger for heating and hot water 28 Fume manifold 29 Fume outlet manifold 32 Heating circulator 34 Heati...

Page 18: ...nozzles G31 mm 11x0 79 LPG supply pressure G31 mbar 37 0 Pressure at LPG burner G31 mbar 35 0 5 0 LPG delivery G31 kg h 2 00 0 65 Heating Maximum working temperature in heating C 90 Maximum working p...

Page 19: ...FUSE CAUTION Before connecting the room thermostat or the remote timer control remove the jumper on the terminal block Fig 8 Key 16 Fan 32 Heating circulator 34 Heating temp sensor 38 Flow switch 42...

Page 20: ...per l evoluzione del prodotto The illustrations and data given are indicative and are not binding on the manufacturer LAMBORGHINI reserves the right to make those changes considered necessary for the...

Reviews: