Key
B
Pressure
point
C
Modureg
cable
D
Protective
cap
E
Minimum pressure adjustment
G
Maximum pressure adjustment
Fig. 3
After checking or adjusting the pressure,
it is mandatory to seal the adjustment
screw with paint or a specific seal.
Max. heating power adjustment
Refer to the Installer parameters menu section
Lighting power adjustment
Refer to the Installer parameters menu section
Installer Parameters menu
The card has 11 transparent parameters that can be modified either by Remote Control (Service parameters
menu) or by itself (Installer Parameters Menu except for the last three: 9,10 and 11):
Num.
Parameters menu
Range
Default
1
Max. heating power
0-100%
100%
2
Gas type selection
0=Natural gas,1=LPG
0=Natural gas
3
Lighting Power
0-60%
50%
4
Heating idle time
0=0minutes, 1=2.5 minutes
1=2.5 minutes
5
Heating pump Post-Circulation
0=0minutes, 1=2.5 minutes
1=2.5 minutes
6
Heating user max. setpoint
30°C, 40°C, 85°C
85°C
7
Hot water user max. setpoint
0=55°C, 1=65°C
0=55°C
8
Heating sensor selection
0=Double sensor,
1=Safety Therm. + Sensor
1=Double sensor
9
Heating ramp
1-20°C/min
10°C/min
10
Mains Voltage Frequency
0=50Hz,1=60Hz
0=50Hz
11
Switching off burner in hot water mode
0=Fixed, 1=Tied to setp.
2=For solar heat. sys.1, 3= For
solar heat. sys.2
1=setp.
Remote Timer Control modification occurs by entering its Service parameters menu (refer to the relevant manual):
the order and range correspond exactly to that given in the table.
Modification from card occurs as follows.
The parameters, named in the previous table P1÷P8, can be displayed and possibly modified from the Installer Pa-
rameters menu by decoding of the LEDs and position, for different time intervals, of the selector. The method for
accessing, displaying and/or modifying a number of parameters and exiting the menu is described by means of the
following flow chart.
• Check that the maximum pressure has not changed.
• Put the protective cap
“D”
back on.
• To end TEST mode, select another mode.
Summary of Contents for Taura 32 MC
Page 91: ...TAURA 32 MC 91 Cod 3540F130 03 2007 Rev 00 2 3 6 IV 25 Fr 6 C 5 C 15 C 7 2 4 7...
Page 97: ...TAURA 32 MC 97 Cod 3540F130 03 2007 Rev 00 3 2 sez 4 4 1 3 4 3 3 1 1 5 bar...
Page 98: ...TAURA 32 MC 98 Cod 3540F130 03 2007 Rev 00 A A B 4 1 A 2 3 B 1 2 3 4 10 15 5...
Page 99: ...3 4 3 led 3 1 RESET 1 RESET led TAURA 32 MC 99 Cod 3540F130 03 2007 Rev 00 20 led led...
Page 104: ......
Page 105: ......