TAURA 32 MC
30
Cod. 3540F130 - 03/2007 (Rev. 00)
A
A
B
Fig. 4
Opening the casing
To open the boiler casing:
1
Unscrew the four screws
A
2
Lower the inspection door
3
Raise and remove the casing
B
Before carrying out any operation inside the boiler, disconnect the electrical power supply and close the gas
cock upstream.
Combustion analysis
To analyse the combustion, you must:
1) Insert the probe in the flue;
2) Open a hot water tap;
3) Adjust the hot water temperature to maximum.
4) Wait 10-15 minutes for the boiler to stabilize*
5) Take the measurement.
Analyses made with an unstabilized boiler can cause measurement errors.
Summary of Contents for Taura 32 MC
Page 91: ...TAURA 32 MC 91 Cod 3540F130 03 2007 Rev 00 2 3 6 IV 25 Fr 6 C 5 C 15 C 7 2 4 7...
Page 97: ...TAURA 32 MC 97 Cod 3540F130 03 2007 Rev 00 3 2 sez 4 4 1 3 4 3 3 1 1 5 bar...
Page 98: ...TAURA 32 MC 98 Cod 3540F130 03 2007 Rev 00 A A B 4 1 A 2 3 B 1 2 3 4 10 15 5...
Page 99: ...3 4 3 led 3 1 RESET 1 RESET led TAURA 32 MC 99 Cod 3540F130 03 2007 Rev 00 20 led led...
Page 104: ......
Page 105: ......