34
300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500
600
500
400
300
200
100
Prevalenza
residua
mbar
Portata (l/h)
DIMENSIONS mm
CIRCULATING PUMP FEATURES
System delivery/pressure
Boiler version:
mod. M type B11 BS
Max. water temperature 90
°
C
mod. MS type C12-C32-C42-C52-C62-C82
Rated gas pressure:G20 20 mbar
Category:
II 2H3+
G30 28-30 mbar/G31 37 mbar
Cl NOx : 1 (M) - 2 (MS)
TECHNICAL FEATURES
Residual pressure
mbar
Delivery (l/h)
XILO T 20 MS W TOP
100 Max. 3000
220
105
440
770
100
Max. 3000
160
330
XILO T 20 M W TOP
220
440
770
160
330
132,5
MODEL
XILO T 20 MS
W TOP
XILO T 20 M
W TOP
Input
Output
Main system
Gas
Supply
kW kcal/h kW kcal/h
Ø
Ø
Ø
kg
26
Return
Ø
kW
kW kcal/h
Cold water
inlet
Operating
pressure
max.
22.360 23.73 20407 12,1 10406 10,47 9004
3/4”
3/4”
3/4”
1/2”
Thermal capacity
Min. thermal capacity
Connections
35
Input
Output
kcal/h
26 22.360 23.66 20348 12,1 10406 10,62
9133
3/4”
3/4”
3/4”
1/2”
33
Bar
3
3
lt
8
Expansion
tank
8
Weight