AXE 3 D UNIT 32 R HR
18
EN
cod. 3541B310 - 10/2011 (Rev. 00)
5.2 Pressure loss
Circulating pumps head/Pressure loss
fig. 24 - Pressure losses
5.3 Technical data table
Data
Unit
Value
Model
AXE 3 D UNIT 32 R HR
Number of elements
no.
3
Max. heating capacity
kW
33.0
(Q)
Min. heating capacity
kW
16.3
(Q)
Max. Heat Output in heating (80-60°C)
kW
32.0
(P)
Min. Heat Output in heating (80-60°C)
kW
16.0
(P)
Max. Heat Output in heating (50-30°C)
kW
33.8
(P)
Min. Heat Output in heating (50-30°C)
kW
17.0
(P)
Efficiency Pmax (80-60°C)
%
97.1
Efficiency Pmin (80-60°C)
%
97.9
Efficiency Pmax (50-30°C)
%
102.7
Efficiency Pmin (50-30°C)
%
103.9
Efficiency 30%
%
103.6
Efficiency class Directive 92/42 EEC
Max. working pressure in heating
bar
3
(PMS)
Min. working pressure in heating
bar
0.8
Max. heating temperature
°C
95
(tmax)
Heating water content
litres
21
Heating expansion tank capacity
litres
8
Heating expansion tank prefilling pressure
bar
1
Protection rating
IP
X0D
Power supply voltage
V/Hz
230/50
Electrical power input
W
320
Empty weight
kg
183
Combustion chamber length
mm
365
Combustion chamber diameter
mm
326
Pressure loss on fume side
mbar
0.11
Type of unit
B
23
PIN CE
0035BU103
0
1
2
3
4
5
6
7
0
0.5
1
1.5
2
Q
[m
3
/h]
H
[m H
2
O]
3
1
2
2.5
3
Summary of Contents for AXE 3 D UNIT 32 R HR