CONCENTRIC FLUE PIPE INSTALLATION
Concentric flue pipe
Fit the concentric elbow pipe in the position required and insert the sealing gasket. Fit the appropriate
diaphragm (see table below).
Fit the air intake and flue pipes, observing the distances indicated on the installation scheme. The flue pipe
should slope slightly outward.
DOUBLE FLUE PIPE
CONCENTRIC FLUE PIPE
1009DIS1074
FLUE
ELBOW
PIPE
Air
diaphragm
ATTENTION: Use only air intake/ fumes evacuation kit produced by
Lamborghini Caloreclima.
CONCENTRIC
CONCENTRIC
DOUBLE
FLUE PIPE
FLUE PIPE
PIPE
Length. 1 mt
Lenght. 3 mt
Diaphragm Ø 77 mm Diaphragm Ø 81 mm Diaphragm Ø 81 mm
(standard)
(standard)
NOTE: Maximum length of concentrical flue pipe is 3 mt.
Maximum length of separate flue pipe (Inlet + Exhaust) is 16.5 mt.
Installing an elbow to connect the boiler to the chimney will cause a
drop in pressure. The values set out in the table below indicate the
necessary modifications to the length of the linear pipes.
INSTALLATION
90
°
ELBOW
45
°
ELBOW
TYPE
FITTING
FITTING
CONCENTRICAL
1 mt
0,5 mt
FLUE PIPE
SEPARATE
0,6 mt
0,3 mt
INTAKE/EXHAUST
1009DIS1273/1
450
360
Max. 3000
250
240
Max. 3000
Ø100
100
860
100
100
Min 500
Ø
100
1009DIS1269/3