Combustion analysis
Two sampling points have been included at the top
of the boiler, one for fumes and the other for air.
To take the samples:
1)
Insert the probes as far as the stop;
2)
Open a hot water tap;
3)
Adjust the hot water temperature to maximum.
4)
Wait 10-15 minutes for the boiler to stabilize*
5)
Take the measurement.
Analyses made with an unstabilized boiler can
cause measurement errors.
Air
Fumes
Fig. 5
Opening the casing
To open the boiler casing:
1
Unscrew the four screws
A
2
Lower the inspection door
3
Raise and remove the casing
B
Before carrying out any operation inside the boiler, disconnect the electrical power supply and close the gas
cock upstream.