10
(95666) TROPOS
Operating Instructions
Operating Instructions
Data logger TROPOS (95666)
9 TROPOS
Module
Depending on order content and purpose the following mod-
ules can be connected to TROPOS:
Id-No.
Basis module “power supply”
TROPOS-PS/1
32.95666.040 010
Power supply standard (weight ~300 g)
100...240 V
AC
/ 24 V
DC
/ 2.5 A incl. fuses and distributer clamps
Add-on modules “power supply”
TROPOS-LF/OP
32.95666.040 050
„Protected variety“ Line fi lter / overvoltage protection
for TROPOS-PS/1 (weight ~400 g)
TROPOS-CC1
32.95666.040 060
incl. charge control (weight ~200 g) and battery (weight ~6.5 kg) for
battery buffered operation for 17 Ah
(backup function UPS)
Basis modules “solar supply”
TROPOS-Solar/1 32.95666.055
010
Solar panel 20 W +
in the housing TROPOS-H integrated
solar battery for 17 Ah (weight ~6 kg)
TROPOS-Solar/2 32.95666.055
020
Solar panel 40 W +
in the housing TROPOS-H integrated
solar battery for 32 Ah (weight ~11 kg)
TROPOS-CC2
32.95666.040 070
Charge control (weight ~200 g) integrated in the housing
TROPOS-H for solar operation, using with TROPOS-Solar 1/2
Basis functions of data transfer
Compact Flash Card (CF card)
32.95666.021 000
for mobile data transfer and for location-independent data evaluation;
range of application -40...+85 °C, industrial standard (1x incl. in the
scope of delivery of TROPOS)
Add-on modules for data transfer
TROPOS-RS 485
(not for solar operation)
32.95666.053 000
Data transfer up to min. 1200 m to a PC, ha mounting into
TROPOS and software connection
*
1)
The visible interface RS 485 is usable only, when this position is
ordered. The interfaces RS 232 and RS 485 are usable parallel, but
not at the same time. A converter RS485/ RS232 is necessary PC-
sided. This item is not included in this position.
Options
TROPOS-RS485/OP
Overvoltage protection
32.95666.053 010
Converter RS485/ RS232
(PC-sided)
00.90249.200 000
Further options
GSM modem
quad band
32.95666.057
000
Incl. antenna with magnetical stand, power cable and mounting
materials
Mounting into TROPOS-H*
2)
or External installation *
3)
Telephone modem
32.95666.051 000
Incl. mounting materials
for use together with power supply units (not solar). An overvoltage
protection for the telephone line is generally recommended, but not
included in this position.
Mounting into TROPOS-H*
2)
or External installation *
3)
Example 2: TROPOS-112 with mains voltage and battery
buffered (unwired)
Example 1: TROPOS-112 with mains voltage (unwired)
Example 3: TROPOS-112 solar powered (unwired)
Example 4: TROPOS ground connection in the housing
8
TROPOS in the housing
(examples)