12 Technical 

data

TROPOS-112

Id-No. 00.95666.500 000

with a processing module and 
an acquisition module 
for up to 1+12 sensors

Range of application:  -30...+60°C 

• 

0...100% r. h. 

• 

no 

condensing 

• 

battery -20...+60°C

Supply voltage: 

10...24 V

DC 

± 2 V

Power consumption: 

Depending on the confi guration:

 

~ 0.5 W (12 V) (solar powered)

 

~ 0.7 W (12 V) (mains powered)

Meas. ranges: 

Depending on sensors - see Table 1, p. 8

1+12 Signal inputs: 

(see page 9)

 

1 Reed* 

Precipitation channel

 

8 analogue  2 of them as Pt 100 · resistor · volt-

age- or current inputs • 4 of them as 
voltage- or current inputs • 2 of them 
as voltage inputs

 

4 digital  

3 of them as counter or for frequen-
cies • 1 input for status

6 outputs: 
 

4 outputs 

For sensor power supply • 3 of them 
switchable via software 

 

1 Relay  

For switching of a communication 
unit (modem)

 

1 OC* 

Open Collector for the output of 
precipitation pulses

Virtual channels: 

Confi gurable

Measuring interval: 

Easy adjustable per channel • 
1/ 10/ 30/ 60 s

Average value interval: Easy adjustable 1...60 min
Extreme values: 

For each average value interval, 
wind peaks per minute

Ring buffer: 

For 1 year 

Memory: 

Compact Flash card (CF card)

Display: 

Easy to read • 2-lines • 16 characters

Operation: 

Via software “

TROPOS-Comman-

der

” confi gurable • via push-/ rotary 

button easy operated

Data transfer: 

Mobile and wireless via CF card • 
With cable via interface RS232 or 
optional via GSM- • telephone- • 
radio modem • RS485

Data evaluation: 

PC evaluation software 
„MeteoWare ...“ (option)

Data format: 

LAMBRECHT proprietary, suitable 
for ASCII export and Excel compatible 

Interfaces: 

RS232 • optional RS 485

Dimensions: See 

Dimensional drawings, page 9

Protection class:  IP 23
Weight: 

Approx. 0.8 kg

Standards: 

Construction- and Low voltage standards: 
72/23 EWG and VDE 0100

 

Stability DIN EN 61000-6-1
Emitted interference DIN EN 61000-6-4

Varieties

TROPOS-124 
Id-No. 00.95666.600 000

like TROPOS-112, 
but with two ac-
quisition modules 
for up to 1+24 
sensors.

Power consumption depending on the confi guration:
 

~ 0.9 W (12 V) (solar powered)
~ 1.2 W (12 V) (mains powered)

In-/ outputs: 

2 acquisition modules, thus 1+ 2x12 

Weight: 

Approx. 1.2 kg

TROPOS-100 - Precipitation-Data logger

Id-No. 00.95666.100 000

like TROPOS-112, but without any acquisi-
tion module and its functions and only one 
processing module. 

Power consumption depending on the confi guration, e.g.

At 10 minutes average   ~ 0.036 W (12 V)

At 1 minute average  ~ 0.12 W (12 V)

In-/ outputs* 

1 Reed contact for precipitation 
events • 1 Open Collector 

Weight: 

Approx. 0.4 kg

* These inputs or outputs are located on the data process-
ing module, all others on the respective data acquisition 
modules.

Summary of Contents for TROPOS-100

Page 1: ...very 4 Commissioning of TROPOS 4 1 Configuration of TROPOS 4 2 Operation via push rotary switch 4 3 The menu items 4 4 Wiring of the TROPOS ports 5 Measurement and evaluation 5 1 The CF card 5 2 Data...

Page 2: ...f 30 60 C The flexible structure enables a high number of measuring ranges namely voltages up to max 5 V currents up to 20 mA resistors up to 5 k as well as frequencies up to 4 kHz The inputs are prot...

Page 3: ...connecting cable null modem adapter TROPOS sided 6 Now the power supply of TROPOS may be switched on TROPOS turns on automatically and the LCD gets active The LCD turns off automatically when there a...

Page 4: ...After pressing the switch it is changing into the edit mode see above chapter 4 2 point 6 By the next rotation of the switch the menu item Date ends and the next menu item Time appears and so on Time...

Page 5: ...f TROPOS the details are described in the following text The software configuration content has to be adjusted ac cordingly The wiring drawings of the factory adjusted sensors are available after soft...

Page 6: ...und referred single ended The reference ground is the input ground on the ports J at the channels A1 and A2 as well as the ports U at the channels A3 A8 All ground ports have to be connected next to t...

Page 7: ...cies pulses or status The digital measuring inputs D1 D4 work ground referred The switching threshold is set to 2 5 V Frequencies up to 4 kHz pulses or status are measurable by the digital channels D1...

Page 8: ...card During CF card exchange TROPOS saves the data of approx 15 minutes on the RAM Within this time period the CF card should be inserted again to avoid data losses Exchange of the CF card see chapter...

Page 9: ...of them switchable via software 2 1 output Relay to switch a communication unit modem A1 A2 2 analogue inputs Resistors up to 250 or e g Pt100 in 2 or 4 wire circuit Resistors up to 2 5 k or e g Pt100...

Page 10: ...location independent data evaluation range of application 40 85 C industrial standard 1x incl in the scope of delivery of TROPOS Add on modules for data transfer TROPOS RS 485 not for solar operation...

Page 11: ...configuration If the mounting is possible the TROPOS Installation 2 is necessary 3 At external installations additional accessories or assembly works could be necessary cables wirings protective devic...

Page 12: ...min Extreme values For each average value interval wind peaks per minute Ring buffer For 1 year Memory Compact Flash card CF card Display Easy to read 2 lines 16 characters Operation Via software TROP...