14
Smart Home Control • Revision: 11-05-2016. • As of version 1.7 Subject to technical modifications and errors.
Multiple drives can be connected at the same
time. Note whether the motor manufacturer
stipulates a group control relay for parallel
connection of motors. Group control relays
can be purchased from Lamilux or the motor
manufacturer.
ATTENTION!
Material damage caused by parallel
connection of unsuitable motors!
Not all drives are suitable for paral-
lel circuitry in drive groups.
• Use appropriate drives or connect the
drives via a group control relay.
Motors with a rated input higher than 400
watts must be operated via a relay or contac-
tor with a separate power supply.
Lamilux offers suitable power supplies for
DC drives. Where applicable, please specify
the motor type, manufacturer and – if availa-
ble – the technical data in any requests for
quotation.
4.5.1 CONNECTION
Connect the mains supply (N/PE/L), weath-
er station (D1/D2), 230-V motors (2/1/
PE/N), 24-V motors (1/2) and LED Strip
Powerbox (D1/D2/L/PE/N) via the supplied
connectors.
ATTENTION!
Material damage caused by incorrect
wiring!
Incorrect wiring can cause permanent dam-
age to the device or electronic devices con-
nected to it.
• Note the labelling of the connection ter-
minals and connect the mains supply,
weather station, drives and equipment
at the intended positions only.
NOTES ON TEACHING IN WIRELESS CONNECTIONS
Teaching of wireless nodes at the terminal unit
is facilitated by protecting the terminal unit and
wireless actuators/sensors with separate cir-
cuit breakers.
To teach the wireless connection to the dis-
play, refer to the section Setting up the wire-
less connection in the manual (basic settings).
The wireless connection to the terminal unit
can be set up in two ways:
1. By pressing the programming button.
This method may only be performed
by a qualified electrician (as per VDE
0100), since the programming button
for the wireless connection is located
on the PCB in the terminal unit.
2. By switching the supply voltage off and
back on.
To enable this method, the terminal unit
should be protected separately (16-A
circuit breaker). Other wireless nodes
should be supplied with power via oth-
er circuit breakers. This means that the
power supply to the terminal unit and the
other wireless devices can be interrupted
independently.
STOP
STOP