20
Smart Home Control • Revision: 11-05-2016. • As of version 1.7 Subject to technical modifications and errors.
A detailed description of the automatic mode
functions can be found in the Automatic win-
dow ventilation section of the manual.
Alarm functions:
Alarm functions have the highest priority and
prevent manual operation of the output.
Wind alarm. Windows closed.
Manual mode: Manual opera-
tion locked. Automatic mode:
Output can be operated if
the automatic wind lock is active.
Frost alarm (combination of precipi-
tation and low outdoor temperature).
Windows closed.
Rain alarm. Window closed or open
in rain position depending on the set-
ting.
Timer functions:
Timed closing or timed opening ac-
tive.
Outside temperature:
Outdoor temperature OK. Ventila-
tion is released. If the icon is not dis-
played, the outdoor temperature lock
is active.
Ventilation function:
Indoor temperature for ventilation ex-
ceeded. Ventilation is performed if all
other conditions are OK.
LIGHT
A detailed description of the automatic
mode functions can be found in the Auto-
matic lighting section of the manual.
Value dropped below dusk threshold.
Light is switched on after a delay of 1
minute. If a lighting period is addition-
ally defined, switching only occurs
within that period.
Lighting period active. If dusk switch-
ing is additionally defined, switching
only occurs at dusk.
HEATING
A detailed description of the automatic
mode functions can be found in the Heating
section of the manual.
Day mode. The preset day tempera-
ture setpoint is effective.
Night mode (night time). The preset
night temperature setpoint is effective.
The value dropped below the currently
valid temperature setpoint. Heating is on.