background image

Dear Customer, Thank you for choosing one of our products, which is a result of technological expertise 

and our continuous quest for superior products in terms of safety, reliability and performance. This manual 

contains all the information and helpful tips for using your product with maximum safety and efficiency. 

IMPORTANT INFORMATION 

This manual has been prepared by the manufacturer and is an integral and essential part of the 

product. In the event of sale or transfer of the product, always ensure the presence of the manual 

as the information it contains is addressed to the purchaser and to all those various people involved 

in the installation, use and maintenance of the product. Carefully read the instructions and 

information contained in this manual before installation, operation and maintenance of the product. 

The instructions contained in this instruction manual guarantee the safety of persons and property 

and ensure efficient operation and a longer service life. The manufacturer declines all responsibility 

for damage caused by failure to observe instructions regarding installation, use and maintenance 

listed in the instruction manual, for unauthorized modifications or non-original replacement parts. 

Product installation and use must be carried out in accordance with the manufacturer's instructions 

and in compliance with European, national and local regulations. Installation, electrical connection, 

functional testing, maintenance and repairs are operations that must be performed by qualified and 

licensed personnel who must have appropriate knowledge of the product. Product installation must 

not be carried out close to walls made of wood or combustible material. For proper installation, you 

must observe the following "Safety distances" section. Verify the exact flatness of the floor where 

you will install the product. When handling the steel parts of the cladding, use clean cotton gloves 

to avoid leaving difficult to remove fingerprints for the first cleaning. Stove installation must be 

performed by at least two people. Connect the stove to the mains only after proper professional 

connection to the chimney flue. The power cable plug must remain accessible after installation of 

the stove. Only operate the stove with regulation wood pellets (refer to the "FUEL" chapter). Never 

use liquid fuels to operate the pellet stove or to stoke the embers present. Provide adequate 

ventilation in the installation area throughout the year. In the presence of operation failures, fuel 

supply will be interrupted. Re-start the unit after removing the cause of the failure. Discontinue use 

of the product in the event of failure or malfunction. Do not remove the safety guard located in the 

pellet tank. Any accumulated unburned pellets in the burner as a result of repeated "failed ignitions 

must be removed prior to ignition." Pellet stove operation can cause very hot heating of the handles, 

the chimney flue and glass surfaces. Only touch these parts during operation when wearing 

protective clothing or with adequate aids. Because of the creation of heat on the glass, make sure 

that no persons unfamiliar with stove operation stand in the installation area. Inform children of the 

precautions to be observed during product operation and of possible dangers. In the event of 

problems or misunderstanding of the instruction manual, contact your dealer. Placing objects which 

cannot withstand heat on the stove or within the minimum required safety range is prohibited. Do 

not open the door during operation or operate the stove with its glass broken. For product terms, 

limitations and exclusions, please refer to the warranty included with the product. In order to pursue 

a policy of constant product development and renewal, the manufacturer may make changes to it 

as deems appropriate without notice. This document is the property of the manufacturer and cannot 

be disclosed in whole or in part to any third party without the written consent of the company, which 

reserves all rights to the rigor of the law. 

Summary of Contents for Jessica Natural SN

Page 1: ...e The instruction manual is an integral part of the product Laminox S r l reserves the right to change the characteristics and data reported in the following document at any time and without warning i...

Page 2: ...gloves to avoid leaving difficult to remove fingerprints for the first cleaning Stove installation must be performed by at least two people Connect the stove to the mains only after proper profession...

Page 3: ...nces for positioning air intake vents Non hermetic installation 11 4 5 Fume exhaust duct 12 4 6 Using an external fume duct 14 5 ASSEMBLY 15 5 1 General notes 15 5 2 Unpacking 15 6 USE 15 6 1 Componen...

Page 4: ...xhaust pipe of the stove and a height no less than the one stated see table 2 Never use two stoves a fireplace and a stove a stove and a wood stove etc in the same room since the draft of one could da...

Page 5: ...tructed so as to prevent penetration into the flue of rain snow or foreign bodies and so that in the event of winds in any direction and at any angle it assures the discharge of combustion products wi...

Page 6: ...ts set out in the paragraphs above The adjacent room cannot be used as a garage for storage of combustible material or for activities involving a risk of fire 1 4 External air intake vent Hermetic ins...

Page 7: ...ncy 88 5 Recommended draft 3 6 Pa Hopper capacity 15 Kg Smoke outlet 120 mm Weight 114 Kg Dimension LxPxH 572 x 553 x 1151 mm 2 3 Product identification data The technical label shows device data and...

Page 8: ...and horizontal splits Since pellet characteristics and quality greatly influence the autonomy efficiency and proper operation of the stove we recommend AVOID using pellets with dimensions different fr...

Page 9: ...d Boilers must be installed in a technical room It is forbidden to install them in open verandas or outdoors Installation in rooms containing other generators that collect air from the environment is...

Page 10: ...lammable material Minimum distance in air from the flammable rear wall P 200 mm Minimum distance in air from the flammable side wall P 200 mm Frontal distance from flammable material R 1000 mm 4 2 3 D...

Page 11: ...and have a thickness of at least 2 mm Fig 5 and 6 Fig 5 Fig 6 4 4 Minimum distances for positioning air intake vents Non hermetic installation Pellet stove combustion air intake vents cannot be connec...

Page 12: ...50 C and are to be secured with a 3 9mm self tapping screw The installation of dampers or valves which may obstruct the passage of exhaust fumes is prohibited Installation in a chimney flue where exha...

Page 13: ...ich is flammable or has flammable parts 100 320 Concrete wall or roof 50 220 Brick wall or roof 30 180 4 5 4 Using a traditional type chimney flue If you wish to use an already existing chimney flue i...

Page 14: ...s steel secured to the building Fig 9 should be used An inspection area should be created at the base of the duct for performing periodic checks and maintenance It should be equipped with a windproof...

Page 15: ...other than that for which it was designed No other fuel besides wood pellets must be used Do not use liquid fuels When the stove is turned on it can reach extremely high temperatures to the touch esp...

Page 16: ...unburned pellets IMMEDIATELY TURN OFF the stove and contact the service centre CAUTION pay the utmost attention when children are present to prevent them from standing in front of the stove 6 1 Compo...

Page 17: ...end until the brazier is filled 2 Lift the pin located on the top of the stove using the starting lever provided and turn it to the locked position Fig 21 22 Fig 21 Fig 22 CAUTION Always remove the st...

Page 18: ...on Max Minimum power position Min Fig 25 6 5 Shutdown By moving the lever in position 1 fig 21 the fall of pellet into the brazier will stop combustion will continue for about 20 minutes after which t...

Page 19: ...or otherwise locally dispersed they should be retained in the closed container until all conders have been thoroughly cooled CAUTION ashes keep embers on for a long time 7 3 Brazier cleaning When the...

Page 20: ...tened with water to clean metal stove parts Never clean metal or ceramic parts with alcohol thinners petrol ketones or other degreasers Use of these substances frees the company from all liability Dis...

Page 21: ...Clean fans thoroughly 7 13 Routine and special maintenance These operations should be programmed ANNUALLY with a Technical Assistance Centre and are necessary to ensure the maintenance of product eff...

Page 22: ...22...

Page 23: ...23...

Page 24: ...Laminox S r l Hydro Division Zona Industriale Callarella 261 263 62028 SARNANO MC Italy Tel 39 0733 657 622 Fax 39 0733 657 494 www laminox com e mail export laminox com Jessica SN rev 07 2022...