LAMONA
Appliances
_ 18
Regulating the minimum
fl
ame
After lighting the burners, turn the control knob
to the minimum setting then remove the knob
(this can easily be removed by applying gentle
pressure).
Using a small «terminal» type screwdriver the
regulating screw can be adjusted as in image
below. Turning the screw clockwise reduces the
gas flow, whilst turning it anticlockwise increases
the flow - use this adjustment to obtain a flame
of approximately 3 to 4mm in length and then
replace the control knob.
When the gas supply available is LPG
-
The screw should be turned clockwise to
adjust. The normal length of a straight flame
in the reduced position should be 6-7mm.
- if the flame is higher then desired turn the
screw clockwise, if it is smaller then turn anti-
clockwise.
For last adjustment bring the burner to high
flame and low flame positions, and check that
the flame is lit.
When you have carried out the new gas regulation,
replace the old gas rating plate on your appliance
with one (supplied with hob) suitable for the type
of gas for which it has been regulated.