The carbon filters (supplied separately)                                                      

                             

Carbon 

 have a limited life. We advise you to change them when there is a noticeable drop in 

performance. The intervals between changing the 

 will depend entirely upon the amount of cooking you 

do, but on average they will last about 3 months. Please quote the part reference number  LAM2003 

(pack of 2) when reordering.

•  To gain access to the carbon filters, first of all remove the grease filters as above.

Remove the old filters and install new charcoal filters by turning them gently.

Refit grease filters.

Reconnect the power supply. 

NOTE:

 The suction will be  lower when installed in recirculation mode, this is normal and not a product fault.

• 

• 

• 

Replacing the lamps                                                                                        

The lamps on this model are 

service fix only and replacement 

should be carried out by an authorised

service agent.

The extractor hood is fitted 2.5W LED lamps which will give many years of reliable service.

In the event of one of the lamps failing please call the service number.

The lamps on this appliance should only be used during operation of the cooker hood. They should not be 

left on permanently and used as a main lighting source. The extractor is for domestic use only.

Only use replacement lamps of type: LSD - F 

                                                              DBS - 2.5/30-H-120/33

                                                              Rectangular LED lamps 2x 2.5W

                                                              AC 220-240V

 

 

 

Before attempting to change or fit the charcoal filters ensure power to the extractor is switched off.

Carbon filters only required for recirculation mode.

Summary of Contents for LAM2412 Stainless Steel

Page 1: ...Instructions and Installation LAM2412 Stainless Steel LAM2413 Black 90cm Chimney Extractor www howdens com appliance registration ...

Page 2: ...See back page for product serial number ...

Page 3: ... you doing your part to protect the environment By placing the marking on this product we declare on our own responsibility compliance to all of European safety health and environmental requirements stated in the legislation for this product Metal Surfaces of the Extractor and Condensation When cooking with pans using a large water content large quantities of vapour and steam can be produced very ...

Page 4: ... a r t x E Control panel layout Care and maintenance General cleaning Grease filters Carbon filters Replacing the lamps Installation Methods of extraction Extraction via ducting Extraction via recirculation Parts indentification Hanging your extractor Decorative chimney fitting Electrical connections 04 04 04 04 04 05 05 05 06 06 06 07 07 08 08 08 08 09 10 11 12 13 13 14 Technical Specification Yo...

Page 5: ... or drugs Product must be disconnected from the mains during installation maintenance cleaning and repair procedures Repair procedures must always be performed by service agents The manufacturer shall not be held responsible for damages arising from procedures carried out by unauthorised persons which may also void the guarantee DO NOT flambè under the extractor Keep all ventilation slots clear of...

Page 6: ...ecirculation Vent 3 Lower Chimney Section 4 Fan and Light Controls 5 Extractor Body 6 Grease Filters 7 Lights General Information Operation Extractor layout Control panel layout 1 Extractor Power Off 2 Extractor Power Level 1 3 Extractor Power Level 2 4 Extractor Power Level 3 5 Extractor Light On Off 1 2 3 4 5 ...

Page 7: ...rer General cleaning Wipe the external surfaces of the appliance regularly using warm water and a mild detergent NEVER use abrasive cleaners or strong household cleaners as they may affect the appearance of the product and or artwork on the control panel voiding the manufacturers warranty Care and Maintenance The grease filters The grease The grease filters should be cleaned every three months or ...

Page 8: ...Thesuctionwillbe lowerwheninstalledinrecirculationmode thisisnormalandnotaproductfault Replacing the lamps The lamps on this model are service fix only and replacement should be carried out by an authorised service agent The extractor hood is fitted 2 5W LED lamps which will give many years of reliable service In the event of one of the lamps failing please call the service number The lamps on thi...

Page 9: ... ventilation in the room when the extractor is used at the same time as an appliance burning gas or other fuels Connect the external ducting kit to the outlet of the extractor Charcoal filters are not required if the extractor is to be ducted out Tips for ducting optimal air extraction Keep duct work short and straight Do not reduce the size or diameter of the duct Keep ductwork taut to minimise p...

Page 10: ...scopic decorative chimney a bag of wall and screws two brackets a ducting connector and reducer 1 3 2 4 5 6 7 8 9 10 1 Main Extractor Body 2 Cable Grid 3 Upper Chimney 4 Lower Chimney 5 Outlet Reducer 6 Chimney Brackets 7 8 4x ST4mm x 30mm Flat Head Body Fixing Screw 4x ST4mm x 40mm Countersunk Wall Bracket Screw 9 6x Chimney Fixing Screws 10 Rawl Plugs ...

Page 11: ... discharged into a which is used for exhausting fumes from appliances supplied with energy other than electricity E g gas boilers Ensure the requirements of the local authorities are adhered to concerning the discharge of exhaust air Ensure adequate room ventilation is provided when the extractor is used in the same room as appliances supplied with energy other than electricity Never duct into a h...

Page 12: ...g externally 4 Rest the chimney sections on the main extractor body and extend the upper section to the ceiling 5 Use the extended chimney sections to mark up the appropriate position of brackets 6 6 Remove the chimney sections drill and secure brackets with appropriate 7 Resit the chimney sections on to the extractor body hooking the lower section on to bracket 6 and secure to the upper wall brac...

Page 13: ... are switched and disconnected at the same time The terminations labelled SUPPLY are the connections for the internal house wiring and the terminations labelled LOAD are for connection to the appliance IMPORTANT The wires in the mains lead are coloured in accordance with the following code Blue Neutral Brown Live Green Yellow Earth As the colours of the wires in the mains lead of this appliance ma...

Page 14: ...ORMATION General Total power consumption 105W Fuse 3 A Voltage Frequency 220 240 V 50 Hz Cable type section 0 75mm 3 core or equivalent Cable length max 1 5m Lamps 2X 2 5W LED warm white 3000k TROUBLESHOOTING GUIDE Symptoms Possible Cause Solutions Lamps fail to operate Light functions but fan does not Lamps internal fault Power is cut extractor will not function Lamp has passed its usable life Mo...

Page 15: ...turer s instructions and used for normal domestic purposes This guarantee does not cover accidental damage misuse or alterations which are likely to affect the product The guarantee is invalid if the product is tampered with or repaired by any unauthorised person The guarantee in no way affects your statutory or legal right What to do if you need to report a problem Please ensure you have ready Th...

Page 16: ...Product serial number Place sticker here ISSUE v2 190219 ...