Exclusive to Howdens Joinery.co
3DJHB
User manual LAM2603
Electrical
Connections
,03257$17(QVXUHWKDWWKHHOHFWULFLW\VXSSO\LVVZLWFKHGRIIEHIRUHFRQQHFWLQJ
<RXUDSSOLDQFHPXVWEHFRQQHFWHGWRÀ[HGZLULQJYLDWKHXVHRIDGRXEOHSROHVZLWFKHGIXVHGVSXURXWOHW
with at least 3mm contact separation, The isolation switch must be accessible after installation. (See
technical data for fuse rating).
:HVWURQJO\UHFRPPHQGWKHDSSOLDQFHLVFRQQHFWHGE\DTXDOLÀHGHOHFWULFLDQ
The terminology DOUBLE POLE -/+ means that both the live and neutral supplies are switched and
disconnected at the same time.
The terminations labelled SUPPLY are the connections for the internal house wiring and the terminations
labelled LOAD are for connection to the appliance.
,03257$177KHZLUHVLQWKHPDLQVOHDGDUHFRORXUHGLQDFFRUGDQFHZLWKWKHIROORZLQJFRGH
Blue..........Neutral
Brown......Live
As the colours of the wires in the mains lead of this appliance may not correspond with the coloured
markings identifying the terminals in your spur box, proceed as follows;
The wire which is coloured blue must be connected to the terminal which is marked with the letter
‘N’ or coloured BLACK. The wire which is coloured brown must be connected to the terminal which is
marked with the letter ‘L’ or coloured RED.
N
L
L
N
LOAD
SUPPLY
LOAD
SUPPLY
DP
250V~
FUSE
ON
Blue.
(Neutral)
Brown.
(Live)
Green / Yellow.
(Earth)