Methods of Extraction      

 

 

 

 

 

 

  

The very best method of clearing the kitchen of unwanted odours is by connecting the appliance to an 
exhaust duct and venting to the outside atmosphere via the ceiling or an exterior wall. Suitable Ducting 
kits  part ref: APL2807 may be purchased from the depot where you bought the extractor. You do not need 

FKDUFRDOÀOWHUVZKHQXVLQJWKHH[WHUQDO'XFWLQJPRGH

Extraction Via Ducting    

              

Ducting mode (APL2807) ducting Kit 
(Supplied Separately) 

Never use the hood in areas where devices with 
exhaust pipes connected to the outside are 
already operating unless perfect ventilation can be 
guaranteed.

‡

Connect the external ducting kit to the outlet 
of the extractor.

&KDUFRDOÀOWHUVDUHQRWUHTXLUHGLIWKHH[WUDFWRU

is to be ducted out. 

Extraction Via Recirculation                

Recirculation mode

&KDUFRDOÀOWHUVUHTXLUHG

For extraction via recirculation, attach charcoal 

ÀOWHUVDERYHWKHPHWDOJUHDVHÀOWHUVVHHSDJH

Part reference HJA2912)  

%HIRUHDWWHPSWLQJWRFKDQJHRUÀWWKH

FKDUFRDOÀOWHUVHQVXUHSRZHUWRWKHH[WUDFWRULV

switched off.

  

‡

5HPRYHWKHJUHDVHÀOWHUV

‡

)LWWKHFDUERQÀOWHUVLQWRWKHDSHUWXUHVHH

page 6.

‡

5HSODFHWKHJUHDVHÀOWHUVEHIRUHWKHSRZHU

supply is turned back on.

Installation

Fig.1b

Fig.1a

Summary of Contents for LAM2603

Page 1: ...User Installation Guide LAM2603 Glass Island Extractor...

Page 2: ...age Warning for possible hazards to health and property Warning possibility of electric shock This product s packaging material is recyclable Help recycle it and protect the environment by dropping it...

Page 3: ...UDFWRU 3DUWV GHQWL FDWLRQ RQWURO SDQHO OD RXW Care and maintenance 06 General Cleaning 06 Grease Filters 06 Carbon Filters 07 Replacing the Lamps 07 Installation 08 Methods of extraction 08 Extraction...

Page 4: ...cohol and or drugs Product must be disconnected from the mains during installation maintenance cleaning and repair procedures Repair procedures must always be performed by service agents The manufactu...

Page 5: ...e 8 Vent Adapter General Information Operation On opening your box you will the extractor body complete with glass canopy a two piece telescopic frame a two piece decorative chimney a bag of and a duc...

Page 6: ...ng Wipe the external surfaces of the appliance regularly using warm water and a mild detergent NEVER use abrasive cleaners Care and Maintenance The Grease Filters The grease is of a metallic material...

Page 7: ...SUL H open the glass cover and trim that sits over the bulb The light bulb can then be pulled away from WKH OLJKW WWLQJ DQG GLVSRVHG RI DSSURSULDWHO Replace the bulb with an appropriate G4 20W max bu...

Page 8: ...in areas where devices with exhaust pipes connected to the outside are already operating unless perfect ventilation can be guaranteed Connect the external ducting kit to the outlet of the extractor KD...

Page 9: ...ort as possible and with the minimum of EHQGV WR SHUPLW VPRRWK DLU RZ 0D LPXP OHQJWK PHWUHV XFWHG DLU PXVW QRW EH GLVFKDUJHG LQWR D XH ZKLFK LV XVHG IRU H KDXVWLQJ IXPHV IURP DSSOLDQFHV VXSSOLHG ZLWK...

Page 10: ...them Pay attention not to insert the screw into the hole marked with an X on the hole template the LQJ PXVW EH LQWR D VXLWDEOH VWUXFWXUH WKDW ZLOO VXSSRUW WKH ZHLJKW RI WKH H WUDFWRU VHFXULQJ WR SODVW...

Page 11: ...part of the telescopic structure C and insert it into the upper structure B Fig 5a Adjust the height of the frame assembly X by referring to the dimensions indicated in Fig 6 and secure it using the...

Page 12: ...I RXU SURGXFW LV VXSSOLHG ZLWK D FRQQHFWRU DQJH W LW WR WKH XSSHU SDUW RI WKH FRRNHU KRRG suction assembly using the 2 screws E Fig 9 E F Fig 9 Fig 8 M P Recirculation installation L WKH H LEOH SLSH W...

Page 13: ...KLPQH SLHFH WR WKH XSSHU RQH DQG LW FDUHIXOO XVLQJ DGKHVLYH WDSH Fig 11a Partially unscrew the 2 screws O a maximum of 3 mm Fig 11a Insert the extractor body into the frame paying attention that the p...

Page 14: ...14 LAMONA Appliances Installing Your Extractor Fix the air evacuation pipe H not supplied RQWR WKH FRQQHFWLRQ DQJH LJ Fig 12 H F F Remove adhesive tape L and rest the lower chimney piece above the coo...

Page 15: ...ame time The terminations labelled SUPPLY are the connections for the internal house wiring and the terminations labelled LOAD are for connection to the appliance 03257 17 7KH ZLUHV LQ WKH PDLQV OHDG...

Page 16: ...any venting is not obstructed OHDQ WKH JUHDVH OWHUV ZLWK ZDUP ZDWHU and mild detergent and or replace any FKDUFRDO OWHUV The extractor works normally but smells linger ORJJHG OWHUV FDQ UHGXFH WKH SUR...

Page 17: ...th the manufacturer s instructions and used for normal domestic purposes This guarantee does not cover accidental damage misuse or alternations which are likely to affect the product The guarantee is...

Page 18: ...www howdens com Page _ 18 LAMONA Appliances...

Page 19: ...Exclusive to Howdens Joinery co Page _ 19 User manual LAM2603...

Page 20: ...If supplied please stick your self adhesive product rating plate here or make a note of the product serial number below in the box below for future reference Serial Number Issue 12 2014...

Reviews: