The ceiling height (A) determines the method of installation.
If ceiling height is less than 2.45m:
‘Top plate’ fixing method (3 x person fit)
Fasten plate to ceiling, struts fasten to extractor, chimney slides over struts, lift whole unit up to fasten to
ceiling plate.
If ceiling height is more then 2.45m:
‘Extractor body’ fixing method (2/3 x persons fit - slightly easier)
Plate & struts fasten to ceiling, chimney sections are placed over struts and secured, then extractor is lifted
up to struts and fastened.
A
Gas Hob
Recommended
750mm Min
Electric Hob
Recommended
650mm Min
X = A - (B+C+37mm)
X = Total length
of struts
X
C
B
37mm
890mm
Installation