Based on the standard Howdens Kitchen Installation Manual set-up of:
Base unit height 890mm
Worktop* 40mm (dependant on worktop chosen)
Rec. Hob Clearance* 750mm
=1680mm
(Height from floor to base of extractor)
2.4m - Ceiling Height Set-Up (= ‘Top Plate’ Fixing)
Build extractor and struts to height of c.720mm
Struts length set to c. 660mm
2.31m - Minimum Ceiling Height Possible (= ‘Top Plate’ Fixing)
Use single struts. Overall extractor height of c. 630mm
(Height is suitable for recirculation installation)
* Remove any loose / dropped screws and nuts etc to avoid possible vibrations / rattles
* Struts must have min. 100mm overlap
Using M4 (10mm) Screws, washers and nuts
Ceiling plate only fastens to the ceiling, assembled extractor and chimney sections are lifted
to fasten to ceiling plate. Upper chimney section is lifted and secured to ceiling plate.
1.
2.
3.
4.
(*Can be reduced to 700mm as a minimum dimension)